Copy a partial parameter set from the control panel to a drive (dL P - Download Partial). The partial set does not inclu-
de user sets, internal motor parameters, parameters 9905...9909, 1605, 1607, 5201, nor any group 51 EXT COMM
MODULE and 53 EFB PROTOCOL parameters. The source and target drives and their motor sizes do not need to be
the same.
Copy USER S1 parameters from the control panel to the drive (dL u1 - Download User Set 1). A user set includes group
99 START-UP DATA parameters and the internal motor parameters. The function is only shown on the menu when User
Set 1 has been first savedusing parameter 9902 APPLIC MACRO (see User macros on page 90) and then uploaded to
panel.
Copy USER S2 parameters from the control panel to the drive (dL u2 - Download User Set 2). As dL u1 - Download
User Set 1 above.
Copy USER S3 parameters from the control panel to the drive (dL u3 - Download User Set 3). As dL u1 - Download
User Set 1 above.
Start, stop, change the direction and switch between local and remote control.
How to upload and download parameters
For the upload and download functions available, see above
Basic Control Panel alarm codes
In addition to the faults and alarms generated by the drive (see chapter Fault tracing), the Basic Control Panel indicates
control panel alarms with a code of the form A5xxx. See section Alarms generated by the Basic Control Panel on page 260
for a list of the alarm codes and descriptions.
.