Mounting The Remote Controller
For exposed type
Preparation: Make 2 holes for screws using a driver.
Mount the top case.
•
Align the claws of the top
case and then align the claws
of the bottom case.
Cut here with
a nipper and
remove the burr
with a fi le.
Claw (2 places)
Connect the remote control
wiring
•
Arrange the wires along the groove
of the case.
Bottom case
(Back side)
For embedded type
Preparation: Make 2 holes for screws using a driver.
Mount the top case.
•
Align the claws of the top
case and then align the claws
of the bottom case.
Avoid the wire
being caught.
Claw (2 places)
Screw
(fi eld supply)
Connect the remote
control wiring
8
Mount the bottom case to
the wall.
U P
Wall to which
the remote
controller is
fi xed
Hole for screw
Claw (2 places)
Screw
(fi eld supply)
Clamper
(fi eld supply)
Pass through
the hole
Remote controller terminal board
Remove the coating. Approx. 6 mm
Top case
(Back side)
Remove the sheath. Approx. 180 mm.
Make sure the wiring connection is in the
correct direction.
Mount the bottom case
to the wall.
•
Pass the wire through the hole
in the centre of the bottom case.
U P
Hole for
screw
Claw (2 places)
Remote controller
terminal board
Remove the coating.
Top case
Approx. 6 mm
(Back side)
Bottom case
(Back side)
Make sure the wiring
connection is in the correct
direction.
Replace The Remote Controller Cover
•
Replace the existing Remote controller cover with Remote controller
cover 6 to close the hole left after remove the Remote controller.
1. Release the Remote controller cover's hooks from behind the
front plate.
Existing Remote
controller cover
2. Press from front to fi x the Remote controller cover 6 on the
front plate.
Remote
controller
cover
6
CHARGING THE WATER
8
•
Make sure all the piping installations are properly done before
carry out below steps.
1. Turn the plug on the Air Purge Valve 9 outlet anticlockwise by
one complete turn from fully closed position.
Air purge valve 9
2. Set the Pressure Relief Valve c level "DOWN".
Lever
Turn up
Pressure relief valve c
3. Start fi lling water (with pressure more than 0.1 MPa (1 bar)) to
the Indoor Unit via water inlet. Stop fi lling water if the free water
fl ow through Pressure Relief Valve drain hose.
4. Turn ON the power supply and make sure Water Pump f is
running.
5. Check and make sure no water leaking at the tube connecting
points.
Front plate
Hook (6 places)
Front plate
Hook (6 places)
Plug (turn
anticlockwise by
one complete turn)
Pressure relief
valve c