see figure 14:
. Technicaldataofthemeasuringaccessories
4mmSafetymeasuringcableATL2
-
S tandard: EN 61010-031,
-
M aximum rated voltage to earth ( ) and measuring category: 1000 V
CAT III, 600 V CAT IV,
-
M aximum rated current: 10 A,
-
P rotective class II ( ), continuous double or reinforced insulation,
-
C ontamination class: 2,
-
L ength: 1.4 m, AWG 18,
-
E nvironmental conditions:
Maximum barometric elevation for making measurements: 2000 m,
Temperatures: 0 °C to + 50 °C, humidity 50 % to 80 %
-
O nly use the measuring cables if in perfect condition and according to this
manual, since the protection provided could otherwise be impaired.
-
T hrow the measuring cable out if the insulation is damaged or if there is a
break in the cable/ plug.
-
D o not touch the bare contact tips of the measuring cable. Only grab the
area appropriate for hands!
-
I nsert the angled terminals in the testing or measuring device.
2. Environmentalnotice
At the end of the product's useful life, please dispose of it at
appropriate collection points provided in your country.
08/ 2007
Assembly of the BENNING MM 8/ 9/ 10
B ENNINGMM8/9/10
20