VOC, Standard 53 Reduction Claims
INFLUENT CHALLENGE
CONTAMINANT
ALACHLOR
ATRAZINE
BENZENE
CARBOFURAN
CARBON TETRACHLORIDE
CHLOROBENZENE
CHLOROPICRIN
2,4-D
DIBROMOCHLOROPROPANE (DBCP)
O-DICHLOROBENZENE
P-DICHLOROBENZENE
1,2-DICHLOROETHANE
1,1-DICHLOROETHYLENE
CIS- 1,2-DICHLOROETHYLENE
TRANS- 1,2-DICHLOROETHYLENE
1,2-DICHLOROPROPANE
CIS-1,3-DICHLOROPROPYLENE
DINOSEB
ENDRIN
ETHYLBENZENE
ETHYLENE DIBROMIDE (EDB)
HALOACENTONITRILES (HAN):
BROMOCHLOROACETONITRILE
DIBROMOACETONITRILE
DICHLOROACETONITRILE
TRICHLOROACETONITRILE
HALOKETONES (HK):
1,1-DICHLORO-2-PROPANONE
1,1,1-TRICHLORO-2-PROPANE
HEPTACHLOR
HEPTACHLOR EPOXIDE
HEXACHLOROBUTADIENE
HEXACHLOROCYCLOPENTADIENE
LINDANE
METHOXYCHLOR
PENTACHLOROPHENOL
SIMAZINE
STYRENE
1,1,2,2-TETRACHLOROETHANE
TETRACHLOROETHYLENE
TOLUENE
TRIBROMOACETIC ACID
2,4,5-TP (SILVEX)
1,2,4-TRICHLOROBENZENE
1,1,1-TRICHLOROETHANE
1,1,2-TRICHLORETHANE
TRICHLOROETHYLENE
TRIHALOMETHANES
XYLENES (TOTAL)
NSF/ANSI STANDARD 53 TEST CONDITION: 60 ± 3 psi, pH 7.5 ± 0.5, 68 ± 5 ºF
For purchases made in the State of Iowa: This form must be signed and dated by the buyer and seller prior
to the consummation of this sale. The seller for a minimum of two years should retain this form on file.
Buyer _________________________________
Name _________________________________
Address _______________________________
City _________ State ___ Zip _____________
Signature ___________
20
Ultrefiner II - FMV
PREMIUM DRINKING WATER SYSTEM
5
MAXIMUM PERMISSIBLE
CONCENTRATION
PRODUCT WATER
mg/L
CONCENTRATION mg/L
0.050
0.001
0.100
0.003
0.081
0.001
0.190
0.001
0.078
0.0018
0.077
0.001
0.015
0.0002
0.110
0.0017
0.052
0.00002
0.080
0.001
0.040
0.001
0.088
0.0048
0.083
0.001
0.170
0.0005
0.086
0.001
0.080
0.001
0.079
0.001
0.170
0.0002
0.053
0.00059
0.088
0.001
0.044
0.00002
0.022
0.0005
0.024
0.0006
0.0096
0.0002
0.015
0.0003
0.0072
0.0001
0.0082
0.0003
0.025
0.00001
0.011
0.0002
0.044
0.001
0.060
0.000002
0.055
0.00001
0.050
0.0001
0.096
0.001
0.120
0.004
0.150
0.0005
0.081
0.001
0.081
0.001
0.078
0.001
0.042
0.001
0.270
0.0016
0.160
0.0005
0.084
0.0046
0.150
0.0005
0.180
0.001
0.300
0.015
0.070
0.001
Date ____________
PERFORMANCE DATA SHEET - page 2 of 3
1. THESE SYSTEMS HAVE BEEN TESTED FOR THE TREATMENT OF WATER
CONTAINING PENTAVALENT ARSENIC (ALSO KNOWN AS As(V), As(+5),
USEPA
OR ARSENATE) AT CONCENTRATIONS OF 0.30 mg/L OR LESS. THIS SYS-
MCL (MG/L)
TEM REDUCED PENTAVALENT ARSENIC, BUT MAY NOT REMOVE OTHER
0.002
FORMS OF ARSENIC. THIS SYSTEM IS TO BE USED ON WATER SUPPLIES
CONTAINING A DETECTABLE FREE CHLORINE RESIDUAL AT THE SYSTEM
0.003
INLET OR ON WATER SUPPLIES THAT HAVE BEEN DEMONSTRATED TO
0.005
CONTAIN ONLY PENTAVALENT ARSENIC. TREATMENT WITH CHLORAMINE
0.04
(COMBINED CHLORINE) IS NOT SUFFICIENT TO ENSURE COMPLETE CON-
0.005
VERSION OF TRIVALENT ARSENIC TO PENTAVALENT ARSENIC. PLEASE
SEE THE ARSENIC FACT SECTION OF THE PERFORMANCE DATA SHEET
0.1
FOR FURTHER INFORMATION.
--------
0.07
2. THE ULTREFINER II IS ACCEPTABLE FOR TREATMENT OF INFLUENT
0.0002
CONCENTRATIONS OF NO MORE THAN 27 mg/L NITRATE AND 3 mg/L
0.60
NITRITE IN COMBINATION MEASURED AS "N" AND IS CERTIFIED FOR
NITRATE/NITRITE REDUCTION ONLY FOR WATER SUPPLIES WITH A PRES-
0.075
SURE OF 280 kPa (40 psig) OR GREATER. ADDITIONAL TREATMENT OR
0.005
INDIVIDUAL DESIGN SHALL BE REQUIRED FOR HIGHER INFLUENT LEV-
0.007
ELS. IF YOU ARE RELYING ON THE ULTREFINER II FOR NITRATE REDUC-
0.07
TION, WE RECOMMEND TESTING YOUR WATER PERIODICALLY (2 TIMES A
YEAR MINIMUM) WITH A NITRATE TEST KIT (SUPPLIED) TO ENSURE THAT
0.10
THE SYSTEM IS PERFORMING PROPERLY. ADDITIONAL NITRATE TEST
0.005
KITS (PART NUMBER 12061) CAN BE PURCHASED FROM YOUR LOCAL
--------
RAINSOFT DEALER.
0.007
3. EFFICIENCY RATING MEANS THE PERCENTAGE OF INFLUENT WATER TO
0.002
THE SYSTEM THAT IS AVAILABLE TO THE USER AS REVERSE OSMOSIS
0.70
TREATED WATER UNDER OPERATING CONDITIONS THAT APPROXIMATE
0.00005
TYPICAL DAILY USAGE.
----------
4. RECOVERY RATING MEANS THE PERCENTAGE OF THE INFLUENT WATER
----------
TO THE MEMBRANE PORTION OF THE SYSTEM THAT IS AVAILABLE TO
THE USER AS REVERSE OSMOSIS TREATED WATER WHEN THE SYSTEM IS
----------
OPERATED WITHOUT A STORAGE TANK OR WHEN THE STORAGE TANK IS
----------
BYPASSED.
5. REDUCTIONS SHOWN ARE FOR VOLATILE ORGANIC CHEMICALS/COM-
--------
--------
POUNDS (VOC) AS PER NSF TABLES. CHLOROFORM WAS USED AS A
SURROGATE FOR VOC CLAIMS REDUCTION. THE ACTUAL REDUCTION
0.0004
RATE OF CHLOROFORM WAS 99.7% AS TESTED BY NSF INTERNATIONAL
0.0002
AT 200% CAPACITY (I.E 450 GALLONS) PER NSF/ANSI 53 STANDARD.
--------
0.05
0.0002
0.04
0.001
0.004
0.10
--------
0.005
1.00
--------
0.05
0.07
0.20
0.005
0.005
0.08
10
Seller ___________________________________
Name ___________________________________
Address _________________________________
City _______ State ____ Zip _______________
Signature _________
Date ______________