• AUTOMATIC DRAIN SHUT-OFF VALVE
• MANUAL FAST FLUSH VALVE
• DAILY PRODUCTION RATE = 16.02 GPD
• EFFICIENCY RATING
• RECOVERY RATING
• MAX TDS LEVEL (PPM) = 1400
• CAPACITY FOR VOC REDUCTION: 225 GALLONS
• OPERATING PSI OF SUPPLY: 40 - 100 PSI (275 - 689 kPa)
• OPERATING TEMPERATURE: 50 - 100 o F (10 - 38 o C)
This system has been tested according to NSF/ANSI 58 for reduction of the
substances listed below. The concentration of the indicated substances in
water entering the system was reduced to a concentration less than or
equal to the permissible limit for water leaving the system, as specified in
NSF/ANSI 58.
LIST OF contaminant
AVERAGE
INFLUENT
CONTAMINANT
CONCENTRATION
(mg/L)
1
0.29
ARSENIC
BARIUM
9.5
CADMIUM
0.031
CHROMIUM
0.3
(HEXAVALENT)
CHROMIUM
0.31
(TRIVALENT)
COPPER
3.0
CYST
26000
FLUORIDE
8.6
LEAD
0.16
2
32
NITRATE/NITRITE
RADIUM 226/228
25 pCi/L
SELENIUM
0.1
TDS
750
TURBIDITY
11 NTU
NSF/ANSI STANDARD 58 TEST CONDITION: 50 ± 3 psi, pH 7.5 ± 0.5, 77 ± 2 ºF
IMPORTANT NOTICE:
READ THIS PERFORMANCE DATA SHEET AND COMPARE
THE CAPABILITIES OF THIS UNIT WITH YOUR ACTUAL
WATER TREATMENT NEEDS. IT IS RECOMMENDED THAT
BEFORE PURCHASING A WATER TREATMENT UNIT, YOU
HAVE YOUR WATER SUPPLY TESTED TO DETERMINE
YOUR ACTUAL WATER TREATMENT NEEDS.
Ultrefiner II - FMV
PREMIUM DRINKING WATER SYSTEM
3
= 17.54%
4
= 37.23%
AVERAGE
EFFLUENT
AVERAGE PERCENT
CONCENTRATION
REDUCTION
(mg/L)
0.002
99.3
0.14
98.5
0.0006
98.1
0.007
97.7
0.003
99.0
0.038
98.7
5
>99.99
0.39
95.5
0.003
98.1
4.2
87
5 pCi/L
80
<0.006
>94.0
27
96.4
0.08 NTU
99.3

PERFORMANCE DATA SHEET - page 1 of 3

• pH RANGE: 2 - 11
• REPLACEMENT FILTERS:
DESCRIPTION
PRE FILTER
MEMBRANE
POST VOC FILTER
THE UNIT SHOULD BE INSTALLED IN AN AREA NOT AFFECTED BY
EXTREME HEAT, COLD, OR THE ELEMENTS. THIS SYSTEM MUST BE
INSTALLED IN ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL
LAWS AND REGULATIONS.
DO NOT USE WITH WATER THAT IS MICROBIOLOGICALLY UNSAFE OR
OF UNKNOWN QUALITY WITHOUT ADEQUATE DISINFECTION BEFORE
OR AFTER THE SYSTEM. SYSTEMS CERTIFIED FOR CYST REDUCTION
MAXIMUM
MAY BE USED ON DISINFECTED WATER THAT MAY CONTAIN FILTER-
EFFLUENT
ABLE CYSTS. THE SYSTEM CONTAINS REPLACEMENT COMPONENTS
CONCENTRATION
(mg/L)
CRITICAL FOR EFFECTIVE REDUCTION OF contaminant. THE WATER
SHOULD BE TESTED PERIODICALLY (2 TIMES A YEAR MINIMUM) TO
0.003
VERIFY THAT THE SYSTEM IS PERFORMING SATISFACTORILY.
0.35
REPLACE ULTREFINER II - FMV MEMBRANE CARTRIDGE 24 TO 36
MONTHS AFTER INSTALLATION, DEPENDING ON WATER CONDITIONS.
0.0011
A WATER TEST FOR TDS REDUCTION IS THE BEST INDICATOR OF
0.013
MEMBRANE PERFORMANCE. REPLACE THE PREFILTER AND POST FIL-
TER CARTRIDGES 12 MONTHS AFTER INSTALLATION OR SOONER
0.006
DEPENDING ON WATER CONDITIONS.
0.069
THE INLET FEED WATER SHOULD BE FREE FROM IRON, MANGANESE,
SULFUR.
21
NSF
CERTIFIED
0.51
PERFORMANCE DATA SHEET, IS BASED ON OPERATION AT DRAIN
SETTING # 2. CERTIFICATION RESULTS DO NOT APPLY TO OTHER
0.019
SETTINGS.
5.2
SEE WARRANTY CARD FOR SPECIFIC WARRANTY INFORMATION
5 pCi/L
NOT APPROVED FOR USE IN CALIFORNIA.
CALIFORNIA-SPECIFIC LITERATURE FROM YOUR LOCAL RAIN-
<0.006
SOFT DEALER.
86
0.26 NTU
PERFORMANCE
DATA,
AS
SHOWN
PLEASE REQUEST
Model ULTREFINER II - FMV - BNFP, ULTRE-
FINER II - FMV - BNFV, ULTREFINER II - FMV
- CHFP and ULTREFINER II - FMV - CHFV are
tested and certified by NSF International
against NSF/ANSI 58 for the reduction of
claims specified on the performance data
sheet.
ITEM#
51635
51637
51636
ON
THE
19

Capítulos

Tabla de contenido
loading

Tabla de contenido