Victron energy BlueSolar MPPT 150/85 Manual Del Usuario página 11

Ocultar thumbs Ver también para BlueSolar MPPT 150/85:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 97
4.3 Charge algorithm
4.3.1. Overview
Several preset charge curves and one user adjustable curve are available, see table
below.
The DEFAULT-setting is algorithm nr 2.
Make sure the charge algorithm is correct for the battery-type that must be
charged. If necessary, contact the battery supplier for the appropriate
battery-settings. Wrong battery settings can cause serious damage to the
batteries.
Algorithm
Description
number
Gel Victron long life (OPzV)
1
Gel exide A600 (OPzV)
Gel MK
Default setting
Gel Victron deep discharge
2
Gel Exide A200
AGM Victron deep discharge
Stationary tubular plate (OPzS)
AGM spiral cell
3
Rolls AGM
PzS tubular plate traction
4
batteries or
OPzS batteries in cyclic mode 1
PzS tubular plate traction
5
batteries or
OPzS batteries in cyclic mode 2
PzS tubular plate traction
6
batteries or
OPzS batteries in cyclic mode 3
Lithium Iron Phosphate
7
(LiFePo
) batteries
4
8 (USr)
do not equalize VRLA Gel and AGM batteries
Table 3: Charge algorithm options. All voltages shown are for a 48V system.
Absorption
and max.
Float
absorption
time
V / h
V
56,4V / 8h
55,2V
57,6V / 8h
55,2V
58,8V / 8h
55,2V
56,4V / 4h
55,2V
57,6V / 4h
55,2V
60,0V / 4h
55,2V
56,8V / 2h
53,4V
Adjustable
Adjustable
(default
(default 57,6V)
55,2V)
Equalisation
Temperature
(Default: off)
compensation
maxV@% of Inom
mV/°C
-65 mV/°C
63,6V@8% max 1h
(-2,7 mV/°C per
cell)
64,8V@8% max 1h
-65 mV/°C
66,0V@8% max 1h
-65 mV/°C
63,6V@25% max
-65 mV/°C
4h
64,8V@25% max
-65 mV/°C
4h
67,2V@25% max
-65 mV/°C
4h
n. a.
0
Adjustable
Adjustable
(default Vabs.+
(default -65
7,2V)
mV/°C)
@25% max 4hrs
11
Tabla de contenido

Solución de problemas

loading

Tabla de contenido