BIG ASS FANS Powerfoil X3.0 Guia De Instalacion página 9

Ocultar thumbs Ver también para Powerfoil X3.0:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

PREPARING THE MOUNTING STRUCTURE: BAR JOISTS
Bar joist mounting guidelines
The fan must be hung from angle irons mounted to bar joists.
The installer must supply the angle irons and angle iron hardware.
Do not install the fan from a single purlin, truss, or bar joist.
Angle iron spans should not exceed 12 ft (3.7 m).
The angle irons must be fastened to the roof structure at each end.
1. Select proper angle irons
Angle Iron Span
(between mounting points)
6 ft (1.8 m) or less
> 6 to 8 ft
(> 1.8 to 2.4 m)
> 8 to 12 ft
(> 2.4 to 3.7 m)
1.
Two pairs of angle irons needed
Minimum Angle Iron Dimensions
(W x H x T)
2.5" x 2.5" x 0.25"
(64 x 64 x 6 mm)
3" x 3" x 0.25"
(76 x 76 x 6 mm)
3" x 3" x 0.25"
(76 x 76 x 6 mm)
WWW.BIGASSFANS.COM
© 2018 DELTA T LLC
Angle Iron Side View
(see table for dimensions)
Height
ALL RIGHTS RESERVED.
Number of Angle
Irons Needed
2
2
4
1
Thickness
Width