3.2. SETTING THE TIME
We start by first setting the Day and Time.
3.2.1 You can do this by Press & Holding the
Config/Prog. button until the following is shown.
3.2.3 Now, hours start to flash. Press the "+" and
"-" button until you reach the correct time (hour)
and Press the OK/Mode button.
If the device is associated with a G-Control Hub, the adjustment of time is removed and the time in the G-Control Hub is
configured in the heater automatically.
3.3. PROGRAMMING
By default, the background economic temperature is applied in all time intervals.
3.3.1 Press & Hold the Config/Prog. button until the following is shown. The first segment will start to flash. By pressing the
OK/Mode button you can select whether you want a Frost setting
(19°C). Now press the "+" button to move to the next 1 hour time interval.
Note: These temperatures can be changed later without adjusting the times.
3.3.2 Once you've gone through all the time intervals for day 1, you will automatically start on day 2. Repeat the above steps
until you go through all 7 days. Once you have configured the desired programming, press Config/Prog button to exit
programming.
3.3.3. Press OK/Mode to select Auto Mode. The heater will start to run the program and the display will flash between the set
temperature for the current day and the word Pro and will show the current time interval to indicate the heater is running the
set program.
3.2.2 Press & Release the Config/Prog. button again and the day of
the week starts to flash. Using the "+" and "-" buttons select today's
date. 1=Monday, 2=Tuesday, Etc. and Press the OK/Mode button.
3.2.4 Now, minutes start to flash. Press the "+" and "-" button until you
reach the correct time (minutes) and Press the OK/Mode button.
.
14
(5°C), Background setting
(17°C) or Comfort setting