Set-Up Of Kli 310/311 To Operate Velux Integra ® Skylights - Velux INTEGRA KLI 310 Instrucciones

Ocultar thumbs Ver también para INTEGRA KLI 310:
Idiomas disponibles

Idiomas disponibles

1
2
1 sec
A
4
5
max 3 sec
22 VELUX
®
3
10 sec
A
1 sec
Set-up of KLI 310/311 to operate VELUX INTEGRA
Important: The wall switch must be the universal KLI 310 or the model
matching the product.
If a non-functional control must be replaced or if the wall switch cannot
find certain products, you can make the products ready for registration
by manually resetting them to initial factory settings.
Note: Reset products cannot be operated until they have been regis-
tered in the wall switch again.
Make sure that the power to the skylight (VSS/VCS) is turned on.
1
Close the sash by pressing the button closest to the center of the
2
skylight (A).
When the skylight is closed, reset the skylight by pressing and hold-
3
ing the button closest to the center of the skylight (A) for at least
10 seconds. The skylight operator will run briefly back and forth
indicating that the skylight is ready to be registered.
Note: The skylight must now be registered in the wall switch within the
next 10 minutes.
4
Press the Pair button on the wall switch for 1 second.
Press the stop key and then the DOWN key within 3 seconds. This is
5
only necessary at the initial set-up after installing the skylight.
The skylight can now be operated by the KLI 310/311.
skylights
®
VELUX
23
®

Hide quick links:

loading

Este manual también es adecuado para:

Integra kli 311Integra kli 312