PREAMPLIFIER INSTALLATION
Plate-Mount Preamplifier Input Connections
1. Detach the preamplifier housing by removing the two Phillips
head screws from the back of the housing.
2. Remove the material from the hole in the center of the cover
plate or the center of the preamplifier housing.
3. Cut the cable to the desired hanging length, allowing for a 76
to 101 mm (3 to 4 in.) service loop.
4. Clamp the strain relief around the cable and insert the strain
relief into the hole.
5. Connect the cable leads to the terminal block (B = Black,
R = Red, S = Shield).
Plate-Mount Preamplifier Output Cable Connections
1. Using professional-quality, two-conductor, shielded micro-
phone cable, thread the output cable from the outside of the
preamplifier through the hole with the black bushing.
2. Connect cable to pins as follows:
Pin 2 = +, Pin 3 = –, Shield = S.
3. Reattach the preamplifier housing.
CEILING TILE INSTALLATION (Figure 4)
Remove: Plate-Mount Preamp Connection
1. Drill a 1/2" hole into the ceiling tile.
CAUTION: To avoid damaging the tile, use a 1/2" augur bit
and drill by hand or very slowly with a variable-speed drill.
2. Unplug the mini 4-pin connector from the preamp and feed the
cable through the hole.
3. Place the rubber grommet, tip down, over the cable and posi-
tion it to suspend the microphone at the appropriate height.
4. Fit the grommet securely into the hole. For 5/8" ceiling tile, use
the supplied washer.
5. Reconnect the Preamp.
INSTALLING THE IN-LINE PREAMPLIFIER (Figure 4)
Use the two supplied mounting clamps to hold the preamplifier in
place on a wall or ceiling.
ADJUSTING PREAMP GAIN: MX202B AND MX202W ONLY
(Figure 5)
MX202B and MX202W microphones include an adjustable gain
preamplifier, allowing the user to specify a 12 dB or 0 dB gain
setting. The preamp ships at 12 dB setting. To reduce the signal
gain at the MX202B and M202W preamplifier by 12dB, replace the
gain resistors to the 0dB setting (Table 5A).
RF FILTERING
MX200 Series must be used with RK100PK or RK202PK
preamplifier, in order to optimize RF immunity.
SPECIFICATIONS
Frequency Response (Figure 7)
50 to 17,000 Hz
Polar Pattern (Figure 8)
Output Impedance
180 Ω actual (EIA rated at 150 Ω)
Sensitivity (At 1,000 Hz, open circuit voltage*)
Cardioid: -35.0 dBV/Pa (17.8 mV)
Supercardioid: -33.5 dBV/Pa (21.1 mV)
Omnidirectional: -27.5 dBV/Pa (42.2 mV)
All values -12 dB at 0 gain
*1 Pascal = 94 dB SPL
Maximum SPL (1 kHz at 1% THD, 1 kΩ load)
Cardioid: 124.2 dB
Supercardioid: 122.7 dB
Omnidirectional: 116.7 dB
All values +6 dB at 0 gain
Equivalent Output Noise (A-weighted)
Cardioid: 28.0 dB SPL
Supercardioid: 26.5 dB SPL
Omnidirectional: 20.5 dB SPL
Signal to Noise Ratio (referenced at 94 dB SPL)
Cardioid: 66.0 dB
Supercardioid: 67.5 dB
Omnidirectional: 73.5 dB
Dynamic Range at 1 kΩ Load
96.2 dB
100 dB at 0 gain
Common Mode Rejection
45.0 dB minimum
Preamplifier Output Clipping Level (1% THD)
-6.0 dBV (0.5 V)
-12 dBV at 0 gain
Polarity
Positive sound pressure on diaphragm produces positive volt-
age on pin 2 relative to pin 3 of output connector.
Power Requirements
11 to 52 Vdc phantom, 2.0 mA
Environmental Requirements
Operating Temperature Range: -18° C to 57° C
(0° F to 135° F)
Relative Humidity: 0 to 95%
Dimensions (Figure 6)
CERTIFICATION
Eligible to bear CE Marking. Conforms to European EMC Directive
89/336/EEC. Meets applicable tests and performance criteria in
European Standard EN55103 (1996) parts 1 and 2, for residential
(E1) and light industrial (E2) environments.
NOTE: For technical data by fax, phone 1-800-516-2525 and
follow the recorded instructions. For additional technical
assistance, phone Shure at (847) 600-2000. In Europe,
phone 49-7131-72140.
Shure, the Shure logo, and Microflex are registered trademarks
of Shure Incorporated.
FURNISHED ACCESSORIES
Snap-Fit Windscreen
Black (1 furnished, 4 in replacement kit) . . . . . . RK183WS
White (1). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95B2064
Preamplifier Kit, Plate Mounted, White
(MX202BP & MX202WP) . . . . . . . . . . . . . . . . . . .RK202PK
Stand Adaptor (MX202B and MX202W) . . . . . . . . . 65B1752
OPTIONAL ACCESSORIES
Desk Stand . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A202BB
REPLACEMENT PARTS
In-Line Preamplifier (Black). . . . . . . . . . . . . . . . . . .RK100PK
In-Line Preamplifier (White) . . . . . . . . . . . . . . . . RK100PKW
Omnidirectional Cartridge
Supercardioid Cartridge
Cardioid Cartridge
Strain Relief (MX202BP & MX202WP) . . . . . . . . . . . 80A479
Clamp (MX202B & MX202WP) . . . . . . . . . . . . . . . . . 80A476
Hang Clip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80B489
2
(Black) . . . . . . . . . . R183B
(White) . . . . . . . . . R183W
(Black) . . . . . . . . . . R184B
(White) . . . . . . . . . R184W
(Black) . . . . . . . . . . R185B
(White) . . . . . . . . . R185W
Tabla de contenido
loading

Tabla de contenido