Heatscope PURE Manual De Instrucciones página 41

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 58
the radiant heater (in cluding accessories) that is to be installed. When installing the unit, use the correct
screws (supplied) for the surface.
Please bear in mind that you only need one fixing bracket to fix your unit safely. Please refer to the mini-
mum installation dimensions for the unit (cf. „spacings").
Acc. to EU 2015/1188 ecodesign directive for energy-related products the application of a thermostat
with a room sensor, weekday control system and window opening detection is mandatory, when installa-
tion a heating unit indoors. This is possible with this HEATSCOPE
available thermostat DEVIreg™ Smart this heater of this series fulfills the conformity of the ecodesign
directive.
HEATSCOPE
®
heaters are basically made for outdoor use – and in most cases they are used outdoors
finally. Due to this they are factory-set delivered without any thermostat control system acc. to EU
2015/1188 ecodesign directive. This is consequent, reasonable and will economise valuable ressources.
Many times a separate temperature system / thermostat acc. to ecodesign directive is already installed
and the heaters should be fit in this system. In this case the customer or the assigned installer is respon-
sible to accomplish the EU standards of the ecodesign directive.
OPERATION, INSTALLATION INSTRUcTIONS AND mIN. DISTANcES
Once you have installed the unit, you can use it for the first time.
®
The HEATSCOPE
features two omnipolar „ON/OFF" switches. You can control the radiant heater manu-
ally using these selector switches on the unit itself.
The unit must be connected to a residual current circuit breaker and a fuse! Install the unit in any indoor
or outdoor areas. The heater is IP65 protected from water jets and dust.
CAUTION: The mounting of the heater on the wall and on the cieling as well as in glass houses and con-
servatories has professionally to be accomplished solely according to the mounting regulations. Specified
safety distances given are min. values and may deviate from the local building and fire safety regulations.
The safety distances as well as the local building and fire safety regulations must be complied with at all
times, leave inproper stated installation settings undone at any time. Deviant installation settings require
the technical approval of the manufacturer. In the case of a deviant installation setting without approval
of the manufacturer danger for people and environment may occur. Warranty and guarantee expires for
all heaters, which are not installed according to this operation and installation manual!
Other protective spacings may need to be taken in accordance with local fire safety regulations, e.g. for
installation on cumbustible surfaces.
All cables must be positioned so that they cannot come into contact with the surface of the radiant hea-
ter at any time. The radiant heater must not be installed directly below a power socket. The sides of the
must be at least 20 cm from any power sockets.
HEATSCOPE
®
Tel.: +49 8104 647090 · Fax: +49 8104 647099 · E-Mail: [email protected] · www.munich-home-systems.de
A M B I E N T H E A T I N G S O L U T I O N S
®
type. In combination with the optional