Performance profil of CoverStar CS500 Coveralls:
Physical data
Abraision resistance
Tensile strenght
Flax cracking resistance
Puncture resistance
Resistance to Ignition
Tear resistance
Seam strenght
Type 6: Spraytest
Type 5: Aerosol inward leakagetest
Penetration resistance
Protection against radioactive particulates
Protection against infective agents
Resistance to penetration by blood
Resistance to penetration by contamina-
ted liquids
Resistance to penetration by biologically
contaminated aerosols
Resistance to penetration by
contaminated solid particles
Surface resistance
Remark: For further information concerning the barrier performances please contact NORDWE
PREPARATIONS BEFORE USE: Do not use incorrect coveralls. In case of aully zipper, seams or any other defect, please
contact NORDWEST. The Correct size combinated with correct dressing and a closed zipper protected by flap assures the
protective performace of the coverall.
LIMITATIONS OF USE: Please ensure that you have chosen the right garment suitable for your job. Foradvice, please contact
your supplier of the garment NORDWEST. The user shall be the sole judge for correct combination of full body protective
coverall and ancillary equipment (gloves, boots, respiratory protective equipment, etc.) and for how long CoverStar CS500
coveralls can be worn with respect to its protective performance, wear comfort and heat stress. NORDWEST shall not accept
any responsibility whatsoever for improper use of CoverStar CS500 coveralls.
STORAGE: CoverStar CS500 coveralls can be stored according to customers storage practices.
DISPOSAL: CoverStar CS500 without harm to the environment. Restictions to disposal result only from contaminants
introduced during use.
Unit
Cycles
N
Cycles
N
N
N
H2S04 30%
NaOH 10%
o-xylene
Butanol-n
kPa
min
log CFU
log CFU
Ω
Result
Test-Method
>1500
EN530 Methode 2
Long 85
EN ISO 13934-1
Transv 51
> 100.000
ISO7854 Methode B
10,8
EN863
Self extingusihing
EN 13274-4
material
Long 52,6
ISO9073-4
Transv 33,3
70
EN 13935-2
EN 14605
EN ISO 13982-2
P
R
0
97
0
98
EN ISO 6530
0
95,9
0
98
Nominal
EN1073-2:2002
Protectionfactor 53,1
EN 14126:2003
20
ISO 16603/16604
> 75
ISO 22610
> 5
ISO 22611
< 1
ISO 22612
≤ 2.5 x 10
EN 1149-1
9
Class
5
1
6
2
pass
2
2
pass
pass
P
R
3
3
3
3
3
3
3
3
2
pass
6/6
6/6
3/3
3/3
erfüllt
.
ST
5