Helvi EXPLORER 120 Manual De Uso página 14

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 52
11 Err12: Q>___Ah
12 Err13: U<__V
13 Err14: Bat_UVP
14 Err15: U<__V
15 Err16: Bat_NOK
16 E r r 1 7 : R e c o v _
NOK
17 Err18: U>0V
E r r 1 9 : C a b l e _
18
NOK
19 Err20: U<__V
20 Err21: U<__V or
Err22: U<__V
21
?
22
?
23
14
Tripping the overcharge
protection
Abnormally low battery
voltage when checking the
charge
Abnormally low battery
voltage during UVP Wake
up
Battery too low
Battery out of order
Battery recovery failure
Presence of a voltage at
the clamp terminals when
calibrating the cables
Cable calibration failure
Triggering of the abnormal
undervoltage protection
Abnormally low battery
voltage during charging
Key not detected
No configuration file (.gfc)
is present on the key
Corrupted file
Presence of a consumer on the battery disrupting
the charge
Battery to be replaced
Battery to be replaced
Presence of a short circuit, check the assembly
Battery to be replaced
Check that the selected mode is compatible with the
battery voltage (e. g. : 24 V battery in 12 V mode)
Battery to be replaced
Battery to be replaced
Battery to be replaced
Check the assembly
Charging cables to be replaced
Incorrect connection, check the assembly
Presence of a short circuit, check the assembly
Battery to be replaced
Presence of a consumer on the battery
Check that the USB key is correctly connected to
the charger.
Check that your files are present at the root of the
USB key. Do not put them in a folder or sub-folder.
The file you wish to download is corrupted. Delete
and reinstall the file on the key.
Tabla de contenido
loading

Productos relacionados para Helvi EXPLORER 120

Tabla de contenido