SPA Control
Enabled/Disabled
V.SPA Time
50 sec
Mode SPA+POOL
Cycle
1h / 03h
Delay time
02 min
Sample Time
30 min
Sample Time SPA
5 min

Defrost Mode

1 / 2 / 3
Radio Channel
00
Test Mode
ON/Off
© ASTRALPOOL 2015 ALL RIGHTS RESERVED. PROPRIETARY DOCUMENT
This screen enables or disables the possibility to
select SPA as an operation mode.
1) Disabled: the unit will work only on Pool
mode.
2) User Control: The unit will be able to work
on Pool or/and Spa water, user selectable.
3) External Control: The unit will work on
Pool or/and Spa by means of external
terminals, see 5.15. (Page 24).
This screen set the time the unit will stop water
flow during a Pool ↔ Spa change. This time
reflects the time needed for the 3 way valves to
switch from Pool ↔ Spa. It is useful to set a time
slightly larger than required to assure that the
change is complete.
This screen sets the timing when the unit is set to
heat Pool and Spa. In this example, the unit will
heat Spa for 1 hour and then will change to heat
Pool for 3 hours. If temperature setting is
achieved, unit will change immediately.
This screen represents the time lapse between
when the machine should activate and when it
really does. This screen only appears if "Comfort
function" is activated.
Only appears if "Comfort function" is activated.
This screen represents time lapse between water
temperature readings. For instance, when water
temp is within set point, unit will check every 30
min whether water has come out of set point.
Only appears if "Comfort function" is activated.
This screen represents time lapse between water
temperature readings in SPA. For instance, when
water temp is within set point, unit will check
every 5 min whether water has come out of set
point.
Depending on the units characteristics 3 types of
defrost can be selected:
1) Fan stop: By air with fan off.
2) Air + Fan: By air with fan on.
3) Cycle inversion: by hot gas by reversing
the frigorific circuit. (only reversible
machines)
This screen sets the radio channel the unit will use
to communicate with the remote. In order to work
properly, remote has to be set to the same radio
channel.
This screen sets if test mode is enabled. Test mode
is reserved for technicians that need to diagnose
the unit.
.