eng
1.3. Area of application
Stainless steel pipes, copper pipes,
Carbon steel pipes of the press fi tting systems
Steel pipes EN 10255 (DIN 2440)
Cast pipes (SML) EN 877 (DIN 19522)
Plastic tubes SDR 11
Multilayer composite tubes
Welded stainless steel drainpipe/downpipe (EN 1124)
Wall thickness, copper pipes, cast pipes (SML)
Wall thickness plastic/composite tubes
Operating temperature range
REMS pipe cutting machines, REMS cordless pipe cutting machine -10 °C – +60 °C (14 °F – 140 °F)
Battery
Rapid charger
1.4. Speed
Cutting wheel idle speed
1.5. Electrical data
REMS Cento, REMS Cento RF,
REMS Due-Cento
REMS Akku-Cento 22 V:
Rapid charger Li-Ion:
1.6. Dimensions
L×W×H:
1.7. Weight
without safety foot switch (without battery)
REMS battery Li-Ion 21.6 V, 5.0 Ah
REMS battery Li-Ion 21.6 V, 9.0 Ah
1.8. Noise information
Acoustic pressure level
Acoustic power level
Acoustic pressure level
1.9. Vibrations
Weighted rms value of acceleration
The specifi ed vibration emission value was measured according to a standard test method and can be used for comparison with another device. The specifi ed vibration
emission value can also be used for an initial estimation of the cut-out.
CAUTION
CAUTION
The vibration emission value may differ from the specifi ed value during actual use of the pipe cutting machine depending on the manner in which the pipe cutting
machine is used. Depending on the actual conditions of use (intermittent mode) , it may be necessary to defi ne safety measures to protect the operator.
2. Start-up
CAUTION
CAUTION
Transport weights above 35 kg must be carried by at least 2 persons.
2.1. Electrical connection
WARNING
WARNING
Caution: Mains voltage present! Before connecting the pipe cutting machine
or the rapid charger, check whether the voltage given on the rating plate corre-
sponds to the mains voltage. On building sites, in a wet environment, indoors
and outdoors or under similar installation conditions, only operate the pipe cutting
machine on the mains with a fault current protection switch (FI switch) which
interrupts the power supply as soon as the leakage current to earth exceeds 30
mA for 200 ms.
Batteries (Fig. 1 (19))
Total discharging by undervoltage
The Li-Ion batteries may not drop below a minimum voltage because otherwise
the battery could be damaged by "total discharge", see graduated charging
state display. The cells of the REMS Li-Ion battery are delivered pre-charged
to approx. 40%. Therefore the Li-Ion batteries must be charged before use and
recharged regularly. Failure to observe this regulation of the cell manufacturer
can lead to damage to the Li-Ion battery by total discharging.
Total discharging due to storage
If a relatively low charged Li-Ion battery is stored, self discharging can lead
to total discharge damage of the battery after longer storage. Li-Ion batteries
must therefore be charged before storing and recharged every six months at
the latest and charged again before use.
14
230 V ~; 50 – 60 Hz; 1,200 W; 5,7 A. Fuse (mains) 10 A (B), intermittent mode S3 20% (AB 2/10 min), protective insulated, radio
interference suppressed, or 110 V ~; 50 – 60 Hz; 1,200 W; 11,4 A. Fuse (mains) 20 A, intermittent mode S3 20% (AB 2/10 min),
protective insulated, radio interference suppressed.
21.6 V ; 5.0 Ah / 21.6 V ; 9.0 Ah.
Input: 100 V – 240 V ~; 50 – 60 Hz; 90 W, Output: 21.6 V – ---, all-insulated, interference-suppressed.
REMS Cento
REMS Cento RF
Ø 8 – 108 mm
DN 6 – 100
Ø ⅛ – 4"
Ø 10 – 115 mm
Ø 14 – 115 mm
DN 50 – 100 mm
Ø 10 – 110 mm
Ø ⅛ – 4"
Ø 10 – 110 mm
Ø 40 – 110 mm
≤ 4.5 mm
≤ 10.0 mm
-10 °C – +60 °C (14 °F – 140 °F)
0 °C – +40 °C (32 °F – 113 °F)
115 rpm
115 rpm
REMS Cento
REMS Cento RF
250×300×250 mm
250×300×250 mm
(10"×12"×14")
(10"×12"×14")
16.8 kg (37 lb)
16.8 kg (37 lb)
L
= 87 dB (A)
= 87 dB (A)
L
L
= 87 dB (A)
= 87 dB (A)
pA
pA
pA
pA
pA
pA
L
= 98 dB (A)
L
= 98 dB (A)
wa
wa
L
= 100 dB (A)
L
= 100 dB (A)
pc peak
pc peak
K = 3 dB (A)
K = 3 dB (A)
< 2.5 m/s²
< 2.5 m/s²
K = 1.5 m/s²
K = 1.5 m/s²
NOTICE
Charge the battery before use. Recharge Li-Ion batteries regularly to avoid
their total discharge. The rechargeable battery will be damaged by exhaus-
tive discharge.
Only use a REMS rapid charger for charging. New Li-Ion batteries and Li-Ion
batteries which have not been used for a long time only reach full capacity after
several charges.
Machine status check, REMS Akku-Cento 22 V
The cordless pipe cutting machine is equipped with an electronic machine
status check (Fig. 1 (18)) by a two-coloured green/red LED. The LED lights
green when the battery is fully or still suffi ciently charged. The LED lights red
when the battery must be charged. If this status occurs during cutting, cutting
must be completed with a charged Li-Ion battery. The LED lights red and the
cordless pipe cutting machine switches off if overloaded. After a short dwell time,
the LED lights green again and the cutting process can be continued. The LED
fl ashes red if the motor temperature has been exceeded. After a cooling time,
the LED lights green again and cutting can be continued. The cooling time is
reduced when the cordless pipe cutting machine is operated in idle mode.
If the cordless pipe cutting machine is not being used, the LED goes out after
approx. 2 hours but comes on again when the cordless pipe cutting machine
is switched back on.
Graduated charging state display (Fig. 1 (20)) of the Li-Ion 21.6 V battery
The graduated charging state display shows the charging state of the battery
with 4 LEDs. At least one LED lights for a few seconds after pressing the key
with the battery symbol. The more LEDs that light green, the higher the charging
state of the battery. If a LED fl ashes red, the battery must be charged.
REMS Akku-Cento 22 V
REMS DueCento
Ø 8 – 108 mm
Ø 54 – 225 mm
DN 6 – 100
Ø ⅛ – 4"
Ø 10 – 115 mm
DN 50 – 100 mm
DN 50 – 200 mm
Ø 10 – 110 mm
Ø 40 – 225 mm
Ø ⅛ – 4"
Ø 10 – 110 mm
Ø 40 – 110 mm
≤ 4.5 mm
≤ 10.0 mm
84 rpm
REMS Akku-Cento 22 V
REMS DueCento
250×330×460 mm
260×430×515 mm
(9.8"×13.0"×18.1")
(10.2"×16.9"×20.3")
16.0 kg (35 lb)
37.0 kg (82 lb)
0.8 kg (1.8 lb)
1.1 kg (2.4 lb)
L
= 87 dB (A)
L
pA
pA
pA
pA
L
= 98 dB (A)
L
wa
wa
L
= 100 dB (A)
L
= 100 dB (A)
pc peak
pc peak
K = 3 dB (A)
< 2.5 m/s²
K = 1.5 m/s²
eng
DN 50 – 150
1½" – 6"
Ø 1¼ – 8"
≤ 5.0 mm
≤ 21.0 mm
115 rpm
= 87 dB (A)
= 87 dB (A)
= 98 dB (A)
K = 3 dB (A)
< 2.5 m/s²
K = 1.5 m/s²