Connect Power - LiftMaster 8500 Manual Del Usuario

Ocultar thumbs Ver también para 8500:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Installation
8

Connect Power

To avoid installation difficulties, do not
run the garage door opener at this time.
To reduce the risk of electric shock, your
garage door opener has a grounding type
plug with a third grounding pin. This plug
will only fit into a grounding type outlet. If
the plug doesn't fit into the outlet you have,
contact a qualified electrician to install the
proper outlet.
There are two options for connecting
power:
OPTION A: TYPICAL WIRING
1.
Plug in the garage door opener into a
grounded outlet.
2.
DO NOT run garage door opener at
this time.
OPTION B: PERMANENT WIRING
CONNECTION
If permanent wiring is required by
your local code, refer to the following
procedure.
To make a permanent connection through
the 7/8 inch hole in the back of the garage
door opener (according to local code):
1.
Be sure power is NOT connected to
the opener, and disconnect power to
circuit.
2.
Remove the garage door opener from
the torsion bar, remove cover screws
and set the cover aside.
3.
Cut the line cord 6" (15.2 cm) above
the strain relief.
4.
Squeeze the strain relief and push
into motor unit, then remove the
strain relief from the line cord.
5.
Install a 90° conduit (not provided)
or flex cable adapter (not provided)
to the 7/8" hole. Reinstall garage door
opener to torsion bar.
6.
Run wires through conduit, cut to
proper length and strip installation.
7.
Strip 1/2" (1.3 cm) of insulation from
the existing black, white and green
wires.
8.
Connect the line to the black wire and
neutral to the white wire with wire
nuts (not provided). Connect ground
wire to the green ground screw.
9.
Properly secure wires under plastic
ties so that they do not come into
contact with moving parts.
10. Reinstall cover.
To prevent possible SERIOUS INJURY or DEATH from electrocution or fire:
• Be sure power is NOT connected to the opener, and disconnect power to circuit
BEFORE removing cover to establish permanent wiring connection.
• Garage door installation and wiring MUST be in compliance with ALL local electrical
and building codes.
• NEVER use an extension cord, 2-wire adapter or change plug in ANY way to make it
fit outlet. Be sure the opener is grounded.
WRONG
RIGHT
RIGHT
Flexible
Conduit
Ground
Tab
16
IMPORTANT NOTE: The model 580LM
Alternate Power Supply may be installed
if an outlet is not located near the garage
door opener. MyQ
continue to work however all other MyQ
devices and TTC will not work if using the
Model 580LM Alternate Power Supply.
WRONG
If you would like to use these features,
contact an electrician to install an outlet
near to the garage door opener.
Green Wire
90˚
Connector
(Not
Provided)
BACK VIEW
Green Ground
Screw
Ground Wire
Black Wire
From Power
Cord
White Wire
From Power
Cord
®
light controls will
®
Black Wire
White Wire

Capítulos