2016 UL 325 Gate Operators require use of LiftMaster
external monitored entrapment protection devices.
This QuickStart is intended to highlight a single gate/door
application. Each application is unique and it is the
responsibility of the purchaser, installer and end user to ensure
that the total gate/door system is installed and operated
properly. Refer to the installation manual for complete
information regarding installation, testing, and programming.
845 Larch Avenue
Elmhurst, Illinois 60126-1196
LiftMaster.com
01-38474
© 2016, LiftMaster – All Rights Reserved
Connect rail to operator.
1
Open the cover.
2
Remove the chain guard.
3
Align the key holes on the end of the rail with the cap screws on the chassis.
4
Attach the rail to the chassis with the hardware provided.
5
Move trolley to within 3 feet (.9 m) of the end of the rail.
6
Wrap the chain around the output sprocket.
7
Adjust the chain tension.
Turnbuckle
8
7
Replace chain guard.
Hex Nut
Top of Rail
1/4" (.64 cm) Max.
Within 3 feet (.9 m)
5
Trolley
Mount the operator.
1
Center the header bracket in the opening and
bolt or weld the header bracket to the wall.
Header Bracket
Header Bracket
INSTALLATION
Chain Guard
2
6
1
3
Cap Screw
4
Carriage Bolt
2
Lift the operator and align with center mark
on ceiling. Bolt the operator to the ceiling.
Concrete Anchor
1/2" x 3 1/2"
Brackets (not provided)
Temporary
Support Post
Install vented plug.
1
Remove the dome plug from the
operator chassis.
2
Remove the solid plug in the gear
reducer and replace it with the vented
plug (provided in bag with manual).
3
Tighten the vented plug with a socket or
Allen wrench.
4
Re-insert the dome plug.
Determine location for operator.
Washer
1
2
With the gate/door closed,
mark the center.
Nut
3
Bolt or weld arm to gate/door.
Flush Mount
Arm
OR
Dome Plug
Vented Plug
Open the gate/door and mark the
center point on the ceiling.
Door Arm
DOOR INSTALLATION
loading

Resumen de contenidos para LiftMaster Elite Serie

  • Página 1 1/4" (.64 cm) Max. Within 3 feet (.9 m) Trolley 2016 UL 325 Gate Operators require use of LiftMaster external monitored entrapment protection devices. Carriage Bolt Mount the operator. Center the header bracket in the opening and Lift the operator and align with center mark Bolt or weld arm to gate/door.
  • Página 2: Wiring And Adjustments

    Select the open speed using the BIPART that the gate/door is stopping at the proper open and close limit system and REQUIRES the addition of a LiftMaster external batteries (see images below). The operator can be wired for 120 DELAY switch.
  • Página 3: Démarrage Rapide

    à l’essai et la programmation. Support du linteau INSTALLATION DE LA PORTE Poteau de 845 Larch Avenue support temporaire Elmhurst, Illinois 60126-1196 LiftMaster.com 01-38474 © 2016, LiftMaster – Tous droits réservés...
  • Página 4 (voir les illustrations s’arrête aux bonnes positions de fin de course d’ouverture et de protection de LiftMaster contre le piégeage (capteur photoélectrique utilisant le commutateur BIPART DELAY. ci-dessous). L’actionneur peut être câblé pour 120 ou 240 V fermeture.
  • Página 5: Instalación

    Montaje a ras sobre la instalación, la prueba y la programación. Brazo Ménsula del cabezal INSTALACIÓN DE LA PUERTA Columna 845 Larch Avenue temporal de soporte Elmhurst, Illinois 60126-1196 LiftMaster.com 01-38474 © 2016, LiftMaster – Reservados todos los derechos de ley...
  • Página 6 (ver las siguientes ilustraciones). El la velocidad de apertura con el relé de retardo BIPART. posiciones. monitoreada de LiftMaster para CADA zona de atrapamiento (sensor operador puede cablearse para 120 o 240 VCA según el RETARDO BIPART DESACT. (preasignado) = fotoeléctrico sin contacto o un sensor de borde) antes de poner el...

Este manual también es adecuado para:

HctdcuHct08Hct10Hct12