TFA_No. 30.3054_Anleit_11_19
KLIMA-MONITOR – Wireless Thermo-Hygrometer
6.7 Maximum and minimum values
• Press the MIN/MAX / – button.
• MAX appears on the display.
• On the display appear the maximum values since the last reset.
• Press and hold the MIN/MAX / – button to delete the maximum values of the cur-
rently selected channel.
• Press the MIN/MAX / – button again.
• MIN appears on the display.
• On the display appear the minimum values since the last reset.
• Press and hold the MIN/MAX / – button to delete the minimum values of the cur-
rently selected channel.
• Press the MIN/MAX / – button again to go back to the display of the present val-
ues.
7. Settings
• The device will automatically quit the setting mode if no button is pressed for a
long period of time.
• Press and hold the MIN/MAX / – or the CHANNEL / + button for a fast running.
7.1 Setting of the alarm for the temperature and humidity
7.1.1 Temperature alarm
• Press the CHANNEL / + button until the arrow appears on the desired channel
(channel 1-3 and internal sensor).
• Press and hold ALARM / SET button for 3 seconds.
• HI AL and 60 °C (default IN: 35°C) or the last adjusted upper temperature limit
appears on the display.
• Press the CHANNEL / + or MIN/MAX / – button to adjust the desired upper temper-
ature limit.
• Press and hold the ALARM / SET button after setting the value when still flashing
to activate the alarm function.
• The alarm symbol appears on the display.
• Confirm the setting with the ALARM / SET button.
• LO AL and -20°C (default IN: 10°C) or the last adjusted lower temperature limit
appear on the display.
• Press the CHANNEL / + or MIN/MAX / – button to adjust the desired lower tempe-
rature limit.
22
09.11.2019
9:59 Uhr
Seite 12
KLIMA-MONITOR – Wireless Thermo-Hygrometer
• Press and hold the ALARM / SET button after setting the value when still flashing
to activate the alarm function.
• The alarm symbol appears on the display.
• Confirm the setting with the ALARM / SET button.
7.1.2 Humidity alarm
• HI AL and 90 % (default IN: 80%) or the last adjusted upper humidity limit appear
on the display (channel 1-3 and internal sensor).
• Press the CHANNEL / + or MIN/MAX / – button to adjust the desired upper humidi-
ty limit.
• Press and hold the ALARM / SET SET button after setting the value when still
flashing to activate the alarm function.
• The alarm symbol appears on the display.
• Confirm the setting with the ALARM / SET button.
• LO AL and 30 % (default IN: 40%) or the last adjusted lower humidity limit appear
on the display.
• Press the CHANNEL / + or MIN/MAX / – button to adjust the desired lower humidity
limit.
• Press and hold the ALARM / SET bSET button after setting the value when still
flashing to activate the alarm function.
• The alarm symbol appears on the display.
• Set the alarm for the additional transmitters and for the internal sensor in the
same way.
• Repeat the above steps until you have set and activate the desired alarms.
7.2 Display of the adjusted alarm values
• Press the ALARM / SET button in normal mode to show the adjusted upper alarm
limits (channel 1-3 and internal sensor).
• Press again the ALARM / SET button in normal mode to show the adjusted lower
alarm limits (channel 1-3 and internal sensor).
• Press again the ALARM / SET button to return to normal display.
7.3 Case of alarm
• In the case of an alarm the corresponding symbol will be flashing and an alarm
sound is activated. Stop the alarm tone with any button.
23