The inverter switches off if:
the battery voltage drops below 10 V (12 Vg connection) or 20 V (24 Vg
connection),
the battery voltage exceeds 16 V (12 Vg connection) or 32 V (24 Vg
connection),
the inverter overheats.
➤ If this happens, shut down the inverter with the main switch (fig. 5 3,
page 4).
➤ Check that the inverter is sufficiently ventilated and that the ventilation
grilles are unimpeded.
➤ Wait 5 – 10 minutes and switch the inverter on again without any electric
consumers.
When operating the inverter at high load for lengthy periods, it is advisable to
start the engine in order to recharge the vehicle battery.
10.3
Configuring the inverter
You can adjust the device using the DIP switch (fig. 5 1, page 4).
Setting the mains voltage
You can set the mains voltage using the S1 and S2 dip switches.
Mains voltage
200 V
220 V
230 V
240 V
EN
DIP switch
S1
Off
On
Off
On
Using the inverter
S2
Off
Off
On
On