F1500-UPS OWNER'S MANUAL
OPERATION
FRONT PANEL DESCRIPTION (See Diagram Of Unit, Page 19)
Power Switch
Press the power button to turn the F1500-UPS ON or OFF.
Menu Navigation Knob
Rotate clockwise to navigate to the next screen, counter-clockwise to return to the previous screen, push to select menu item.
IR Detector
IR Detector, for sampling IR remote control signals.
Removable Battery Access Panel
Easy to remove for battery access and replacement.
FRONT PANEL DISPLAY LED DESCRIPTIONS (See Diagram Of Unit, Page 19)
Status Display
LCD displays status and menu navigation items
Outlet Bank 1 Indicator
Illuminated blue when outlet bank 1 is switched on
Outlet Bank 2 Indicator
Illuminated blue when outlet bank 2 is switched on
Outlet Bank 3 Indicator
Illuminated blue when outlet bank 3 is switched on
Outlet Bank 4 Indicator
Illuminated blue when outlet bank 4 is switched on
Line Fault Indicator
This LED will illuminate in red to warn the user that a wiring problem such as a bad/missing ground or reversed wiring exists within
the AC receptacle. If illuminated, disconnect all equipment and contact an electrician to insure outlet is properly wired.
REAR PANEL DESCRIPTION (See Diagram Of Unit, Page 19)
Outlet Bank 1 - Critical Load Outlets
Two battery powered, SMP protected outlets for critical-load equipment insures temporary uninterrupted operation of connected
equipment during a power failure.
Outlet Bank 2 - Critical Load Outlets
Two battery powered, SMP protected outlets for critical-load equipment insures temporary uninterrupted operation of connected
equipment during a power failure.
Outlet Bank 3 - Non-Critical-Load Outlets
Two battery powered, SMP protected outlets for connected equipment insures temporary uninterrupted operation of connected
equipment during a power failure. These outlets will shut off when the batteries drain to a designated level to reserve remaining bat-
tery charge for the critical load outlets.
Outlet Bank 4 - Non-Critical-Load Outlets
Two battery powered, SMP protected outlets for connected equipment insures temporary uninterrupted operation of connected
equipment during a power failure. These outlets will shut off when the batteries drain to a designated level to reserve remaining bat-
tery charge for the critical load outlets.
IR Control Section
Indicator LED's – Indicates status
IR Output Jacks – Standard 1/8" (3.5mm) mono jack for connection to an IR flasher (IR flashers not included)
8