en
Description of device
A
Insertion funnel
B
Conductor stop, adjustable,
min. 3,5 – max. 13 mm
C
Adjusting screw
D
Cutting edge
E
Hand lever
F
Grip flap
Tool set-up
1
• Open grip flap F.
2
• Press the cross-section dial J.
3
• Turn in the direction of arrow and set to the proper ferrule size.
Then release the cross-section dial J.
Please note: In order to guarantee proper function, the cross-section dial (J)
must now be re-locked into place.
4
• Adjust control gate I to size of ferrule.
• This will ensure that the ferrule chain K runs properly.
5
• Insert the ferrule chain K flat into the guide of the enclosure, so that the first ferrule
lies in the crimping die of crimping drum G.
• Turn down the free end of the ferrule chain K as shown in Figure 5.
Close grip flap F.
Cutting: flexible conductor with cross-sectional area (CSA) between
0.5 and 2.5 mm
2
6
Insert the conductor into the guide, and press hand lever E.
Insulation stripping: conductor with CSA between 0.5 and 2.5 mm
7
• Adjust variable conductor stop B to the length of insulation stripping.
For ferrules this is usually 10 mm.
8
• If necessary, use adjusting screw C to adjust the insulation stripping tool to the
insulation thickness required.
Crimping: wire end ferrules with CSA between 0.5 and 2.5 mm
9
• Insert the stripped conductor straight into the ferrule through lateral opening A.
• Applying slight pressure, displace crimping drum G in the direction of the
conductor and keep under pressure.
• You will see that dial J is laterally displaced in the direction indicated by the
arrow. This will increase the distance from the enclosure.
• In this position, hand lever E must be pressed as far as it will go.
• The locking device then releases hand lever E so that it can be opened.
10
• Re-open hand lever E and remove the conductor with the crimped ferrule.
Modifying the tool for use with other cross-sectional areas
Open grip flap F, remove the ferrule strip, and continue as described under
"Tool set-up".
Storage: store the tool only in open condition.
Replacing cutting edge
11
• Loosen the screw, and withdraw cutting edge D, screw and socket.
12
• Insert replacement cutting edge D, socket and screw, tighten screw.
Releasing the locking device
13
• The tool has an automatic lock that ensures the desired crimping quality is
achieved.
The automatic lock is released using a screwdriver (release opening H)
G
Crimping drum
H
Release opening
I
Control gate for selecting
ferrule size
0,5 mm
J
Dial for adjusting cross-sectional area
K
ferrule chain
8
2
to 2,5 mm
2
2
2