Important; Functioning; Troubleshooting - Maico AWB 100 C Instrucciones De Montaje

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 58
2
ENGLISH
Versions
Standard
Version with timer
Adjust the trimmer (screw) illustrated in the figure to in-
crease or decrease the delay in turning off the device
(from 3 to 25 minutes).
14
ON
OFF
Version with humidity control and timer
This version is equipped with timer and humidistat. See
the preceding point for the functioning of the timer.
To adjust the humidistat, regulate the adjustment trim-
mer (screw) illustrated in the figure to increase or de-
crease the humidity threshold that makes the appliance
intervene automatically. The humidity sensor is adjust-
able from 40% to 90% of Relative Humidity.
It is possible to control the appliance from a remote
switch if it is connected as indicated in figure 10/3.
IMPORTANT: it is not possible to switch off the ap-
pliance by the remote switch if the level of environ-
mental humidity is more than the set threshold.

Troubleshooting

PROBLEM
The appliance does not
switch on
The impeller does not turn
CAUSE AND REMEDY
There is no voltage.
Check the main switch and/
or the electrical connections.
Check that its movement is
not slowed down.
Tabla de contenido
loading

Tabla de contenido