battery in a room temperature environment. Please half charge before
EN
storage and charge the battery for 2 hours every 2 months.
Troubleshooting
PROBLEM
POSSIBLE CAUSE
The battery pack
The battery pack
charge is reduced
has automatically
after more than
performed self-
one month of non-
maintenance to
use.
extend its life.
The battery
pack is over
The battery pack
temperature
LED is flashing red.
or under
temperature.
6
cramer.eu
SOLUTION
Fully recharge the battery
pack before use.
Allow the battery pack to
reach normal temperature.
Move battery pack to a
surrounding air temperature
of above 5 °C (41°F) or
below 52 °C (125.6 °F).
Technical Data
PROPERTY
Model
82V220
72V
Battery
Voltage per cell
3.6V
Number of cells
20
Charge time
45 min. (use 82C2 / 82C1G Charger)
RF output power
- 8.01 dBm
RF frequency range
2402.0 - 2480.0 MHZ
Model
82V430
72V
Battery
Voltage per cell
3.6V
Number of cells
40
Charge time
90 min. (use 82C2 / 82C1G Charger)
RF output power
- 8.01 dBm
RF frequency range
2402.0 - 2480.0 MHZ
VALUE
3Ah, 216Wh, 82V MAX
6Ah, 432Wh, 82V MAX