Using Pump with AstralPool compliant external control
AstralPool manufactures Salt Chlorinators, e-Quilibrium chemical dosing units or the Viron Connect Touch
Screen Control system which can control both the operating times of the all Viron eVo pumps PLUS the speed
the pump operates at during each timer period.
For the P320 & P600 you must enable the communication port and disable the Pump in built timers.
1.
Toggle MENU until CONF (configure) appears. Hold ENTER for 3 seconds.
2.
Toggle MENU until "TMR" appears.
3.
Press UP or Down buttons to turn "TMR" off. Remember, you are now using the external control to set the
pump operating hours, so the pump timer must be turned off.
4.
Press ENTER to accept.
5.
Toggle MENU until "SYS" (system) appears. Press the
Viron P320 or P600 eVo will accept the start, end and pump speed instructions from the AstralPool
compliant control chlorinator e-Quilibrium dosing controller or Viron Connect Touch Screen Control.
6.
Press
"auto" to return to main menu.
7.
The time will still be visible on the LCD display however, the timer function in the menu setting will no
longer appear. Toggle the MENU button will now only display PRIM (priming program), CLK (clock setting)
and CONF (Configuration menu).
8.
Refer to your AstralPool compliant Chlorinator, e-Quilibrium Dosing Control or Viron Connect Touch
Screen Control manual for details of programming the pump speed and operating hours.
Fault Codes
The P320 & P600 Pump only
Fault Code (displayed on screen)
HI T
HI A
Lo V*
BSUC
*Please note: It is normal for the "Lo V" fault code to display briefly on start up.
Data cable connector:
If a compatible AstralPool VX Salt Chlorinator, Viron Salt Chlorinator or Viron Connect Touch Screen, is
connected with the AstralPool communication cable, the speed of the pump and operating hours can be
controlled by these devices.
The Viron P320 & P600 eVo must have its inbuilt timer deactivated if the pump operating times and speeds are
to be operated by the compatible AstralPool Salt Chlorinator, e-Quilibium Dosing Controller or Viron Connect
remote touch screen.
Installation and General Maintenance Manual – Viron eVo Pool Pump
up or down
button and turn to "ON". The
Meaning
Over Temperature
Over Current
Under Input Voltage
Motor is Stuck
14