RFL Electronics RFL 9300 Manual De Instruccion página 169

Sistema de comparación de carga
Tabla de contenido
#
PARAMETER
020
Phase Bias
022
Bias Control
024
Bias/Ground Dly
026
F.D. Ground
028
Phase O/C Bkup
030
Phase TOC
032
PhTOC Curve
034
Ground TOC
036
Gd TOC Curve
038
Overhd/Undergd
041
Comms Alm Dly
046
Transmit Addr 1
050
Guard/Trip
121
Current Time
122
Reset Disp. Alrm
141
Slctv Pole RL
999
System Label
9300>
Figura 6-13. Menú de lectura típico de ajustes para el modo de tres terminales, disparo monopolar.
#
PARAMETER
020
Phase Bias
022
Bias Control
024
Bias/Ground Dly
026
F.D. Ground
028
Phase O/C Bkup
030
Phase TOC
032
PhTOC Curve
034
Ground TOC
Gd TOC Curve
036
038
Overhd/Undergd
(1)
040
Stub Bus
044
Beeper
047
Transmit Addr 2
120
Current Date
122
Reset Disp. Alrm
145
Trip Release
999
System Label
9300>
Figura 6-14. Menú de lectura típico de ajustes para el modo de tres terminales, disparo tripolar.
Las siguientes notas aplican a las figuras 6-11 a la 6-14
1. Si Stub-Bus (parametro #40) esta activo, El respaldo (parametror #27) mostrara un ajuste de SBACTIVE. Esto
indica que el relevador ha sido puesto en modo de respaldo. Ver sección 3.13 para mas información.
2. Si el parámetro #30 esta inhabilitado, entonces los parámetros 31, 32 y 33 mostrara N/A(no aplica).
3. Si el parámetro #34 esta inhabilitado, entonces los parámetros 35, 36 y 37 mostrara N/A(no aplica).
RFL 9300
30 de enero de 2002
B e c a u s e R F L ™ a n d H u b b e l l ® h a v e a p o l i c y o f c o n t i n u o u s p r o d u c t i mp r o v e me n t , we r e s e r v e t h e r i g h t t o c h a n g e d e s i g n s a n d s p e c i fi c a t i o n s wi t h o u t n o t i c e .
SETTING
1.500 Amps
Disable
.05/.05 sec
1.0 Amp
31.875 Amps
(2)
Disable
N/A
(3)
Disable
N/A
Overhead
Disable
4079
Disable
09:29:27
No
Disable
Gen1
SETTING
1.500 Amps
Disable
.05/.05 sec
1.0 Amp
31.875 Amps
(2)
Disable
N/A
(3)
Disable
N/A
Overhead
Inactive
Disable
4075
08/16/00
No
CS+TRIP
Gen1
#
PARAMETER
021
Ground Bias
023
Ground Delay
025
F.D. Phase
(1)
027
Backup
029
Ground O/C Bkup
Ph TOC Pickup
031
033
Ph TOC Dial
Gd TOC Pickup
035
037
Gd TOC Dial
(1)
040
Stub Bus
044
Beeper
047
Transmit Addr 2
Current Date
120
Single Pole
140
145
Trip Release
#
PARAMETER
021
Ground Bias
023
Ground Delay
025
F.D. Phase
(1)
027
Backup
029
Ground O/C Bkup
031
Ph TOC Pickup
033
Ph TOC Dial
035
Gd TOC Pickup
Gd TOC Dial
037
039
Open Conductor
Comms Alm Dly
041
046
Transmit Addr 1
050
Guard/Trip
121
Current Time
140
Single Pole
6-43
SETTING
1.500 Amps
Enable
8.0 Amps
Enable
31.000 Amps
N/A
N/A
N/A
N/A
Inactive
Disable
4075
08/16/00
Active
CS+TRIP
SETTING
1.500 Amps
Enable
8.0 Amps
Enable
31.000 Amps
N/A
N/A
N/A
N/A
Alarm
Disable
4079
Disable
10:12:58
Inactive
RFL Electronics Inc.
(973) 334-3100
Tabla de contenido
loading

Tabla de contenido