Electronic display magnetic strip MA508
2.15 Position of the decimal point
Description
no decimal point
1 Decimal place: "0,0"
2 Decimal place: "0,00"
3 Decimal place: "0,000"
The Position of the decimal place is only used for being indicated on
the display and is not considered for the calculation.
2.16 Counting direction (see mechanical mounting)
Description
Counting positiv
Counting negativ
2.17 Reset Delay
Description
The reset function of the MA508
is triggered after short actuating
of the "reset" key (<1 sec.)
The reset function of the MA508
is triggered after longer actua-
ting of the "reset" key (>2 sec.)
2.18 Trouble shooting
Error description
•
"ERROR" display cannot be
deleted.
•
Displayed value does nor
correspond to the position
after calibration of the
system and traveling of the
sensor.
•
The battery symbol appears
after switching on the LC
display.
20. September 2011
Menu text PTM
"dP.0"
"dP.1"
"dP.2"
"dP.3"
Menu text PTM
"Zr.uP"
"Zr.dn"
Menu text PTM
"rd.no"
"rd.On"
Possible causes/
remedy
•
Distance or angle between
active sensor surface and
magnetic strip is outside the
mounting tolerances.
•
Control resolution parame-
ter and check whether it is
usable for the application.
•
Optimize distance or angle
between sensor surface and
magnetic strip.
•
Change battery.