Trouble shooting
0 =
Carry out compensation
1 =
Compensation completed
0 =
Switch off compensation again after the
measuring run.
Note: The present operating mode cannot be
transferred to the permanent memory.
Code C8
Selecting the limit (threshold) value for suppression of
minor unbalance readings in grams, or ounces. The
unit of measurement (g or oz) depends on the setting
F
(
5.12.3).
Grams:
Range 3.50 to 20.0 g
Factory-adjusted to 5.0* g
Select another limit, e. g.: 5.50 g
• Select Code C8
• Set the value 5.50
• Press ENTER
Ounces:
Range 0.12 to 0.71 oz
Factory-adjusted to 0.18* oz
Select another limit, e. g.: 0.50 oz
• Select Code C8
• Set the value 0.50
• Press ENTER
Note: The selection is permanently acquired.
* = Factory adjusted mode