Classeq Pass Through Range - User Manual
Problem
Possible Cause
Warewasher is
Drain Pump failure.
over filling
E16
Warewasher does
Warewasher not
not heat up.
turned on.
Warewasher not
able to fill.
Warewasher still
going through fill /
heat cycle.
Excessive foam in
Wrong type of wash
and/or rinse aid
Wash Tank.
chemicals.
Wash and/or rinse
aid chemical
injection rate too
high.
Wash Tank not fully
heated.
Wrong type of
Prewash
Solution / Check
Attempt to drain
the warewasher
(►6.9). If
warewasher does
not drain, stop
the warewasher
and request a
service callout.
Check that the
indicators and
display on the
Control Panel are
illuminated.
Press the On/Off
button.
Ensure the water
supply is turned
fully on.
Ensure the water
supply hose has
not been trapped
or kinked.
Check that the
site water supply
has not been
turned off.
Check that the
site water
pressure is
adequate
(►4.7.1).
Check that
Fill/Heat indicator
is flashing amber.
Allow enough
time for the
warewasher to fill
and heat (►6.3).
Check that the
wash and/or rinse
aid chemicals are
commercial ware
washer grade.
Always use the
correct grade of
chemicals.
Check / adjust the
injection rates of
the wash and
rinse aid
chemicals.
Check Wash Tank
temperature on
Control Panel
display.
Do not prewash
with soap based
detergent.
Problem
Possible Cause
Cycle does not
Warewasher not
start.
turned on.
(The warewasher
has a heat
interlock that will
delay the start of
the wash cycle
until all cycle start
Warewasher still
criteria have been
going through fill /
met. When the
heat cycle.
criteria have been
met the heat
indicator will
illuminate green
and the cycle
should start. If this
is not the case
please check the
below items
before requesting
a service callout.)
Wash Tank not full.
Solution / Check
UK
Check that the
indicators and
display on the
Control Panel are
illuminated.
Press the On/Off
button.
Check that
Fill/Heat indicator
is flashing amber.
Allow enough
time for the
warewasher to fill
and heat (►6.3).
Please refer to the
latest version of
the Engineers
Manual on the
Classeq website
for full
information
regarding
temperatures and
interlock settings.
Ensure the water
supply is turned
fully on.
Ensure the water
supply hose has
not been trapped
or kinked.
Check that the
site water supply
has not been
turned off.
Check that the
site water
pressure is
adequate
(►4.7.1).
23