Priming The Chemical Pumps; Integral Water Softener (If Fitted) - Classeq P500 Manual De Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 37
5.4

Priming the Chemical Pumps

Before the warewasher can be used the chemical tubes need to
be filled with chemicals, in order to do this you will need to follow
the instructions given below to prime the chemical pumps.
Enter Commissioning Mode - press and hold the Exit (1) and
Enter (2) buttons simultaneously for 3 seconds (►5.2).
Using the Up and Down keys (5 and 6), scroll to the rinse aid
prime menu (rP0) and press Enter (2)
The display will flash and will change to 1.
This will start and run the Rinse Aid Pump for a maximum of 12
minutes, drawing chemical into the warewasher. When the
chemical has reached the back of the warewasher (the chemical
is visible through the tubing), press Enter (2) again to stop the
Pump.
The display will stop flashing and revert to rP0.
Using the Up and Down keys (5 and 6), scroll to the detergent
prime menu (dP0) and press Enter (2).
The display will flash and will change to 1.
This will start and run the Detergent Pump for a maximum of 2
minutes, drawing chemical into the warewasher. When the
chemical has reached the back of the warewasher (the chemical
is visible through the tubing), press Enter (2) again to stop the
Pump.
14
Classeq Pass Through Range - User Manual
The display will stop flashing and revert to dP0.
Press Exit (1) until the warewasher exits Commissioning Mode
and returns to the off state.
5.5

Integral Water Softener (if fitted)

5.5.1
Commissioning the water softener unit
To commission the Water Softener unit follow the instructions
below:
1.
Lift up the Hood to the warewasher.
2.
Remove the Basket Ramp.
3.
Remove the Salt Reservoir Cap at the front right hand
corner of the Wash Chamber.
4.
Fill the Reservoir with fresh water.
5.
Using the Water Softener Funnel supplied, fill the
Reservoir with approximately 1.5kg of granulated salt.
6.
Wipe away any excess or spilt salt from the Wash
Chamber and the Reservoir opening.
7.
Refit the Salt Reservoir Cap, ensuring that the Cap is
fitted flat and secure.
8.
Do not overtighten the Salt Reservoir Cap.
9.
Replace the Basket Ramp.
Caution
DO NOT run the
in the salt reservoir, as this will allow limescale
to build up. Limescale deposits in the
warewasher
warewasher
if there is no salt
will invalidate the warranty.