on the remote control to arm the alarm and OFF to disarm. The delay time
for entering and leaving the protected area is between 20~25 seconds.
7. It's recommended to test the alarm system for correct operation with first
use and every 3 months.
Procedure:
a) Switch on the alarm unit to ALARM or CHIME (for testing recommend).
b) Push the ON button on the remote control to arm the alarm.
c) Wait for 20~25 seconds (delay time).
d) For testing door/window sensor, open every door or window one
by one and check if the corresponding LED lights up and the CHIME
sounds.
e) For testing PIR sensor, move around the PIR sensor and check if the
corresponding LED lights up and the CHIME sounds. Note: the LED
indicator on the PIR sensor lights up also.
f) Disarm the alarm if everything operates correct.
g) The alarm system is ready to use.
Note:
1) The alarm unit will give a conformation tone when armed or disarmed. The
tone for CHIME is different as for ALARM.
2) If a sensor does not need to be switched on, it's possible to switch off every
sensor individually with the on/off switch. In this case the sensor is no part
of the alarm system anymore when armed (except PIR sensor).
3) A sensor switched to RF+ALARM will always give an alarm sound on the
sensor itself, unless the alarm unit is armed or disarmed.
4) When a sensor is triggered and the siren of the alarm unit sounds, it needs
to be switched off with on/off switch of the alarm unit. After that the alarm
unit can be switched on again. When the alarm keeps on going after arming
the system, check if every sensor is installed properly.
Specifications:
Alarm unit (figure 1):
Power:
Standby current:
Chime current:
Alarm current:
Alarm volume:
4.5 V DC (3x battery AA, not included)
<1.5 mA
<90 mA
<130 mA
100 dB (0.5 m)