Description remote control (SAS-ALARM100/110/120):
Figure 5
Off button
Installation SAS-ALARM100
1. Insert, according the diagram inside the battery compartment, (backside)
the batteries for the alarm unit (3x AA).
2. Install the door/window sensor with the adhesive tape to doors and
windows. Note: maximum 1 cm distance between magnetic contact and
sensor (see figure 2). Switch on the sensor to RF or RF+ALARM. If switched
to RF+ALARM, the sensor will send, when triggered, a signal to the alarm
unit and the siren of the sensor itself will also sound. In this case the siren of
the sensor and the alarm unit will both sound.
3. Remove the transparent front cover of the alarm unit to write down the
position of the sensors corresponding with the numbered LED. (e.g. sensor
1=front door, 2=kitchen window, etc.).
4. Install the alarm unit to a location. The distance between the alarm unit and
the most far away door/window sensor may not exceed 60 m (open area)*.
5. Switch on the alarm unit to ALARM or CHIME function. If switched to
CHIME, the alarm unit will sound like a door bell when a door or window is
opened. Switched to ALARM generates a 100 dB loud siren. When the alarm
unit is switched on, the alarm is not armed (active) yet. Push the ON button
on the remote control to arm the alarm and OFF to disarm. The delay time
for entering and leaving the protected area is between 20~25 seconds.