Programming
Step Programming
Programming a Supply Step – Models
with 8 Supplies
On models equipped with 8 supplies the WE-6
computer is capable of controlling 8 separate
supplies, and up to 31 various combinations of
the 8 supplies. See the Supply Display Codes
table in this subsection for a listing of the
energized supply compartments represented by
each display code. The supplies are divided into
2 separate banks of 4 supplies each. Supply 5
acts as a switching function between the 2
banks of supplies and is counted as one of the
31 combinations, as it can be programmed
alone for special applications.
The LED display will indicate the combination
of supply compartments that will energize for
that particular supply. For example, when a
Supply 3 (first supply bank, third supply signal)
is programmed, the display reads "S3nncc,"
with "nn" representing the step number and
"cc" representing the cycle number. Supply 3
flushes supply compartment 3. When Supply 7
(second supply bank, second supply signal) is
selected, the display reads "S7nncc." See the
Supply Designations table in this subsection for
a full explanation of the 8 available supplies.
To program a supply in the first supply bank,
follow this procedure:
1. The computer must be in PROGRAM
mode and the cycle programming sequence
must be ready for the next step.
2. Press the Supply key. The display will read
"S-nncc." Press key 1, 2, 3, or 4, whichever
corresponds to the appropriate supply valve
to be turned on. If key 4 is pressed, for
example, the display will read "S4nncc."
46
)
(Continued
3. Press the Enter key. The display will read
"M---S." Now enter the time in minutes
and seconds that the supply injection
should last.
4. Press the Enter key and go to the next step
of the cycle.
The supplies in the second bank operate in the
following manner:
Note: To energize the second bank of
supplies, press the Supply key and key 5.
Supply 5 serves only as a switching function
between the first and second supply banks, and
is not an actual supply output.
1. The computer must be in PROGRAM
mode, and the cycle programming
sequence must be ready for the next step.
2. Press the Supply key followed by key 5 to
switch from the first supply bank to the
second supply bank. The display will read
"S5nncc." Now press key 1, 2, 3, or 4,
whichever corresponds to the appropriate
supply valve to be turned on. Pressing key 1
will energize the first supply signal of the
second supply bank, supply signal 6. The
display will read "S6nncc." Pressing key 2
will energize the second supply signal of
the second supply bank, supply signal 7.
Pressing key 3 energizes the third supply
signal of the second bank, supply signal 8.
Pressing key 4 energizes the fourth supply
signal of the second bank, supply signal 9.
F232050