Application
Operation is possible in conjunction with:
• Pressurized storage heaters
Operation is not possible with:
Low-pressure storage heaters (displacement water heaters)
The water filtrate is classified as Category 2 according
to EN 1717.
Safety notes
Avoid danger due to damaged power cords. In the
case of damage, the control unit must be replaced by
the manufacturer or his customer service department
or an equally qualified person.
• The filter system must always be operated with cold water
of foodstuff grade.
• The control unit and plug must not be directly or indirectly
sprayed with water when cleaning.
• The control unit must be connected to a permanent power
supply.
• At the installation location, the filter system must be
protected against mechanical damage, heat and direct
sunlight.
Do not install near heat sources or an open fire.
• Installation of the faucet with filter cartridge is only
permitted in frost-free rooms.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty.
Specifications
Electrical data:
• Voltage supply:
• Power consumption:
• Standby power loss:
• Type of protection
– Control unit:
– Mains plug:
Sanitary data:
• Flow pressure:
– min.
– recommended
• Operating pressure
– Faucet:
– Filter cartridge and filter head:0.2 – 0.8 MPa (29 – 116 psi)
• Test pressure of faucet:
If static pressures exceed 0.5 MPa (72 psi), a pressure-
reducing valve must be installed.
Avoid major pressure differences between hot and cold water
supply.
• Max. flow faucet (tap water):
6.6 L/min or 1.75 gpm/0.41 MPa (59 psi)
• Flow rate (GROHE Blue
®
water):
• Ambient temperature:
1
English
• Temperature
• Adjustable bypass, factory setting:
• Filter capacity at bypass setting 2
• Water connection:
Electrical test data
• Software class:
• Contamination class:
• Rated surge voltage:
• Temperature for ball impact test:
The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage and rated
current.
Electrical installation
100 - 240 V AC / 50/60 Hz
9 W
< 1.0 W
Installation
Refer to the dimensional drawing on fold-out page I.
IP 68
IP 40
Install faucet, see fold-out page II, Figs. [1] and [2].
Important: The cable must not be pinched.
Flush piping system prior and after installation of faucet
0.1 MPa (14.5 psi)
thoroughly!
0.2 – 0.5 MPa (29 – 72 psi)
Install control unit, see Figs. [3] and [4].
Important: Do not connect voltage supply yet.
max. 0.8 MPa (116 psi)
Connect faucet, see Figs. [2], [5] to [7].
1.6 MPa (232 psi)
Open hot and cold water supply and check connections
for leakage.
Connect voltage supply via mains plug, see Fig. [8].
The display illuminates and the remaining filter capacity is
displayed in percent.
approx. 0.9 gpm
39 – 90 °F
– Hot water inlet:
– Recommended (energy saving):
(Carbonate hardness 10 - 24 °KH):
corresponds to max. 12 months
Electrical installation work must only be
performed by a qualified electrician and in
accordance with National Electric Code
and/or local requirements!
max. 158 °F
140 °F
2
max. 198 gallons
cold - blue
hot - red
A
2
2,500 V
100 °C