1 PRESCRIPTIONS
1.1 SAFETY PRESCRIPTIONS
This installation manual is addressed exclusively
to professionally skilled personnel. Read all
the instructions carefully before starting the
installation procedures. Any operations that are
not expressly set down in these instructions
are to be considered prohibited; improper use
may result in damage to the product and place
persons and property at risk. The manufacturer
declines all liability for failure to observe best
practices in gate construction and for any
possible deformation that may occur during
use of the product. Store this manual in a safe
place for future reference. The design and
construction of the devices of which model
EAGLE is composed and this manual are in full
compliance with statutory legislation.
In consideration of potential hazards that may
arise during the installation and use of EAGLE,
also the installation procedures must be carried
out in full compliance with the applicable laws,
standards and regulations; namely:
1.2 INSTALLATION PRESCRIPTIONS
• Before starting the installation procedures
make sure you have any additional devices
and materials that may be required to
complete the automation system with EAGLE
in consideration of the specific application.
• The automation system must not be used
until the system has been commissioned.
• Dispose of packaging materials in compliance
with local regulations.
1.3 OPERATING PRESCRIPTIONS
• No modifications can be made to any part of
the product unless specified in this manual.
Unauthorized modification of the product is
likely to lead to malfunctions. The manufacturer
declines all liability for damage caused by
unauthorized modifications.
• The parts of the automation system must
never be immersed in water or other liquids.
During the installation procedures ensure that
no liquids penetrate inside the control unit or
other open devices.
• If liquids penetrate any parts of the automation
system disconnect the electrical power supply
immediately and consult the technical service;
the use of EAGLE in such conditions may give
rise to potentially hazardous situations.
• Keep all parts of EAGLE away from heat
sources and open flames; exposure to heat
or flames may damage the devices and cause
faults, fire, or hazardous situations.
• When the equipment remains unused for a
long time, remove the optional battery and
store it in a dry place to avoid the risk of
leakage of harmful substances.
• Connect the control unit exclusively to an
electrical power supply line equipped with an
efficient protective earth conductor.
• Any operations that require the housing of
EAGLE to be opened must be performed with
the control unit and the electrical power supply
disconnected; if the disconnect device is not
clearly visible from where you are working,
attach a warning notice to the effect:
"WARNING - MAINTENANCE IN PROGRESS".
• In the case of tripping of circuit breakers or
blowing of fuses, find the fault and remedy it
before resetting the circuit breaker or changing
the fuse.
• If the fault cannot be remedied using the
information given in this manual, consult the
technical service.
2 PRODUCT DESCRIPTION AND
INTENDED USE
2.1 PRODUCT DESCRIPTION
Concealed underground electromechanical operator designed to automate
gates or doors with swing leaves up to 3.5 metres. Supplied in 24V and
230V versions complete with coupling and mechanical closing stop.
COMUNELLO ®Copyright 2017 - All rights reserved
13