Sensor-Specific Parameters - Balluff BIP LD2-T -03-S75 Serie Manual De Instrucciones

Ocultar thumbs Ver también para BIP LD2-T -03-S75 Serie:
Tabla de contenido
BIP LD2-T_ _ _-03-S75
Inductive Positioning System
6
IO-Link interface (continued)
6.5
System parameters
Index
Parameters
Hex
Dec
000D 13
Profile characteristic
000E 14
PDInput descriptor
Tab. 6-5:
System parameters
6.6

Sensor-specific parameters

Index
Parameters
Hex
Dec
0052 82
Temperature array
Internal temperature
Min. temperature startup
Max. temperature startup 03
Min. temperature lifetime
Max. temperature lifetime 05
0055 85
Application specific
number
0056 86
COMx speed
0057 87
Operating hours array
Total hours
Maintenance hours
Startup hours
0058 88
Startup array
Total startups
Maintenance startups
00C0 192
Gradient
00C1 193
Offset
00C5 197
Inversion
00C8 200
Slmin[mm]
Slmax[mm]
00CA 202
Teach-in Status
Please note that floating point values have Little-Endian coding and start with the LSB.
1)
Tab. 6-6:
Sensor-specific parameters
www.balluff.com
Subindex
Parameters
Hex Dec
01
1
DeviceProfileID
02
2
FunctionClassID
03
3
FunctionClassID
01
1
PDV1
02
2
PDV2
Subindex Data format
(length)
Hex Dec
00
0
Char (5 bytes)
01
1
Char (1 byte)
02
2
Char (1 byte)
3
Char (1 byte)
04
4
Char (1 byte)
5
Char (1 byte)
0
0
Char (1 byte)
00
0
Char (1 byte)
00
0
12 bytes
01
1
UInt32 (4 bytes)
02
2
UInt32 (4 bytes)
03
3
UInt32 (4 bytes)
00
0
8 bytes
01
1
UInt32 (4 bytes)
02
2
UInt32 (4 bytes)
00
0
Float32
(4 bytes) Read only
1)
00
0
Float32
(4 bytes) Read only
1)
00
0
UChar (1 byte)
01
1
Float32
(4 bytes) Read only
1)
02
2
Float32
(4 bytes) Read only
1)
0
0
RecordT
Data format
Access
UINT16
Read only
OctetStringT 3
Read only
Access
Value
Comments
range
Read only
–128...+127 Output of all
temperature
parameters (in °C)
Read/
0...255
Write
Read only
2
IO-Link COM speed
Read only
Sensor operating hours
Read only
Lifetime operating hours
Read only
Operating hours since
last maintenance
Read only
Operating hours since
last startup
Read only
Sensor startup numbers
Read only
Lifetime number of
startups
Read only
Number of startups
since last maintenance
Gradient of curve
(Output → Position)
Curve offset
(Output → Position)
Read/Write 0x00-0x01
Curve inversion
0...133
Current value for
Slmin[mm]
0...133
Current value for
Slmax[mm]
Read only
Current status for linear
Teach-in
english
Comments
Smart Sensor Profile
Process value
Process data
variable
OutOfRange
Position value
13
Tabla de contenido
loading