If the appliance is installed across a wall and
wall tiling, to ensure correct operation a spacer
must be fitted to compensate for any differences
in the surface levels.
The appliance can also be installed on a ceiling
(except model PIR). For ceiling mounting a
special gasket contained in a kit to be ordered
separately must be used in order to maintain a
protection rating of IPX4.
Do not install the appliance on a ceiling without
first inserting the relevant gasket.

MODELS

A. Standard Model
This model is operated by switching it on by
means of the power switch.
B. Timer Model
This model is equipped with a timer factory-set for
a minimum operating time of 3 minutes. The timer
can be adjuste to settings between approx. 3 and
20 minutes by means of the trimmer (see fig.
14A).. The appliance switches on automatically a
few seconds after the light is switched on and
continues to run for the set time after the light is
switched off.
C. T HCS Model
The appliance features a relative humidity sensor
that is factory set at 60%. When relative humidity
exceeds that level, the appliance automatically
starts up. This threshold setting can however be
modified by the installer to 4 levels: 60%, 70%,
80% and 90% (fig. 14B). The circuit is also
equipped with a timer that can be adjusted to
settings between approx. 3 and 20 minutes by
means of the trimmer (see fig. 14B). The unit
switches on automatically a few seconds after the
light is switched on and continues to run for the
preset period of time after the light is switched off.
D. Model PIR
The product is equipped with an electronic circuit
with a sensor (PIR), which brings the unit into
operation when it detects the presence of a person
within its range of action (see page 74-75).
This model is equipped with a timer factory-set for
a minimum operating time of 3 minutes. The timer
can be adjuste to settings between approx. 3 and
20 minutes by means of the trimmer (see fig. 14A).
EN
19