2. DESCRIPTION
2.1 General
Bluetooth built-in: fully configurable with a tablet or smartphone
Low battery voltage alarm trip and reset levels
•
Low battery voltage cut-off and restart levels
•
Dynamic cut-off: load dependent cut-off level
•
Output voltage: 210 - 245V
•
Frequency: 50 Hz or 60 Hz
•
•
ECO mode on/off and ECO mode sense level
Alarm relay
•
Monitoring:
In- and output voltage, % load and alarms
•
For more information, refer to the
VE.Direct communication port
The VE.Direct port can be connected to a computer (VE.Direct to USB interface cable
needed) to configure and monitor the same parameters.
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many
years.
The inverters are short circuit proof and protected against overheating, whether due to
overload or high ambient temperature.
High start-up power
Needed to start loads such as power converters for LED lamps, halogen lamps or electric
tools.
ECO mode
When in ECO mode, the inverter will switch to standby when the load decreases below a
preset value (min load turn on level: 10VA; and min load turn off level: 0VA). Once in standby
the inverter will switch on for a short period (adjustable, default: every 3 seconds). If the load
exceeds a preset level, the inverter will remain on.
Remote on/off
A remote on/off switch can be connected to a two pole connector, between battery plus and
the left hand contact of the two pole connector or between battery minus and the right hand
contact of the two pole connector
LED diagnosis
See section 3.3
To transfer the load to another AC source: the automatic transfer switch
For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax
features a very short switchover time (less than 20 milliseconds) so that computers and other
electronic equipment will continue to operate without disruption. Alternatively use a MultiPlus
with built-in transfer switch.
VictronConnect
manual.
3