4.2 Connection of Battery cables

In order to fully utilize the full capacity of the product, batteries with sufficient capacity and
battery cables with sufficient cross section should be used. See table.
Recommended
cross section (mm
)
2
length up to 6 m
Recommended
cross section (mm
2
)
0 – 5 m
5 -10 m
12/1600
Recommended
battery capacity
300 - 800
(Ah)
Recommended
battery capacity
400 - 1200
(Ah)
Remark: Internal resistance is the important factor when working with low capacity batteries.
Please consult your supplier or the relevant sections of our book "electricity on board",
downloadable from our website.
Procedure
Proceed as follows to connect the battery cables:
Use an insulated box spanner in order to avoid shorting the battery.
Avoid shorting the battery cables.
Connect the battery cables: the + (red) and the - (black), to the battery see appendix A.
Reverse polarity connection (+ to – and – to +) will cause damage to the product.
Secure the nuts tightly in order to reduce the contact resistance as much as possible.
8
12/1600
24/1600
50
25
12/3000
24/3000
95
50
120
95
24/1600
150 - 400
12/3000
24/3000
200 - 700
48/1600
12/2000
25
70
48/3000
35
70
48/1600
12/2000
75 - 200
350 - 1000 200 - 500
48/3000
100 - 400
24/2000
48/2000
35
25
24/2000
48/2000
100 - 250
Tabla de contenido