8.1.3. Cutting very narrow workpieces
(Fig. 31)
Be sure to use a push block when making
longitudinal cuts in very narrow workpieces
with a width of 30 mm and less.
The low guide face of the parallel stop is best
used in this case.
There is no push block supplied with the
saw! (Available from your specialist dea-
ler) Replace the push block without delay
when it becomes worn.
8.1.4. Making angular cuts (Fig. 32)
Angular cuts must always be used using the par-
allel stop (7).
Set the blade (5) to the desired angle. (See
7.5.)
Set the parallel stop (7) in accordance with
the workpiece width and height (see 7.3.1)
Carry out the cut in accordance with the work-
piece width (see 8.1.1., 8.1.2 and 8.1.3.)
8.1.5. Making cross cuts (Fig. 33)
Slide the angle stop (28) together with the
stop rail (27) into one of the grooves in the
saw table (1) and adjust to the required angle.
(See 7.4.) If you also want to tilt the blade (5),
use the groove which prevents your hand and
the cross stop from making contact with the
blade guard.
If necessary, position the stop rail (27) so that
it cannot collide with the saw blade when you
make your cut.
Press the workpiece firmly against the stop
rail (27).
Switch on the saw.
Push the angle stop (28) and the workpiece
toward the blade in order to make the cut.
Important: Always hold the guided part of the
workpiece. Never hold the part which is to be
cut off.
Push the angle stop (28) forward until the
workpiece is cut all the way through.
Switch off the saw again. Do not remove the
offcut until the blade has stopped rotating.

9. Replacing the power cable

If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel
to avoid danger.
Anl_TE_TS_1825_U_SPK7.indb 31
Anl_TE_TS_1825_U_SPK7.indb 31
GB
10. Cleaning, maintenance and
ordering of spare parts
Always pull out the mains power plug before star-
ting any cleaning work.
10.1 Cleaning
Keep all safety devices, air vents and the
motor housing free of dirt and dust as far as
possible. Wipe the equipment with a clean
cloth or blow it with compressed air at low
pressure.
We recommend that you clean the device im-
mediately each time you have finished using
it.
Clean the equipment regularly with a moist
cloth and some soft soap. Do not use
cleaning agents or solvents; these could at-
tack the plastic parts of the equipment. Ensu-
re that no water can seep into the device. The
ingress of water into an electric tool increases
the risk of an electric shock.
10.2 Carbon brushes
In case of excessive sparking, have the carbon
brushes checked only by a qualifi ed electrician.
Important! The carbon brushes should not be re-
placed by anyone but a qualifi ed electrician.
10.3 Maintenance
There are no parts inside the equipment which
require additional maintenance.
10.4 Transport
Only ever transport the machine by lifting it by
the saw table. Never use the safety devices
such as the saw blade guard and stop rails for
handling or transporting purposes.
Suitable lifting points are marked with arrows
on the saw table.
Secure the equipment against slipping; tie it
down securely.

10.5 Ordering replacement parts:

Please quote the following data when ordering
replacement parts:
Type of machine
Article number of the machine
Identification number of the machine
Replacement part number of the part required
For our latest prices and information please go to
www.isc-gmbh.info
- 31 -
21.01.13 08:52
21.01.13 08:52
Tabla de contenido
loading

Este manual también es adecuado para:

43.405.60Te-cc 1825 u

Tabla de contenido