Technical Data - Kollmorgen KCM-S200 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Kollmorgen
2.2.5
Handling
2.2.5.1
Transport
Climatic class 2K3 according to EN61800-2, IEC 60721-3-2
Temperature:
Humidity:
If the packaging is damaged, check the module for visible damage. Inform the cou-
rier and, if necessary, the manufacturer.
2.2.5.2
Storage
Climatic class 1K4 according to EN61800-2, IEC 60721-3-2
Storage temperature:
Humidity:
Only in the manufacturer's original packaging, max. stacking height: 10 boxes
Storage period > 1 year: Prior to commissioning, capacitors must be re-formed. Dis-
connect all electrical connections. Supply the KCM with max. 200 V DC at the
+/- DC terminals for approx. 1 hour per year of storage.
2.2.5.3
Maintenance/Cleaning
Maintenance and cleaning may only be performed by qualified personnel
Clean the housing with isopropyl alcohol or similar; do not immerse or spray
2.2.5.4
Uninstallation
1. Discharge the device safely (see chapter "Discharging KCM modules" on p.18)
2. Leave discharge aids (plug-in bridge, connecting cables) plugged in
3. Check that DC+/DC-, DC+/PE, and DC-/PE are de-energized
4. Remove wiring, dismantle KCM module
2.2.5.5
Repairs/Disposal
Repairs must only be performed by the manufacturer; opening the devices will invalidate
the warranty. In accordance with the WEEE-2002/96/EC directives, we take old devices
and accessories back to dispose of them professionally, provided that the transport costs
are borne by the sender. Please send devices for repair or disposal to:
2.3

Technical Data

Type
Storage capacity
Rated supply voltage
Peak supply voltage
Power
Protection class
Inception voltage
Wiring cross section
Dimensions (HxWxD)
Weight
Permissible ambient temp.
Instruction Manual
08/2014
-25 to +70°C, max. 20 K/hour variable
Relative humidity 5% to 95% non-condensing
KOLLMORGEN Europe GmbH, Pempelfurtstr. 1, D-40880 Ratingen
KCM Capacitor Modules
-25 to +55?, max. 20 K/hour variable
Relative humidity 5% to 95% non-condensing
DIM KCM-S200 KCM-P200 KCM-E200 KCM-E400
Ws
1600
2000
V=
V=
max. 950 (for 30s in 6min)
kW
18
18
V=
evaluated
470
mm²
mm
300 x 100 x 201
kg
6.9
6.9
°C
2000
4000
max. 850
18
18
IP20
-
-
6 max.
4.1
6.2
0 ... 40