Installation Requirements

LOCATION REQUIREMENTS

Consider all of the following when selecting an
installation location for the water softener.
Do not locate the water softener where
freezing temperatures occur. Do not
attempt to treat water over 120ºF. Freezing
temperatures or hot water damage voids
the warranty.
To condition all water in the home, install
the water softener close to the water supply
inlet, and upstream of all other plumbing
connections, except outside water pipes.
Outside faucets should remain on hard water
to avoid wasting conditioned water and salt.
A nearby drain is needed to carry away
regeneration discharge (drain) water. Use a
floor drain,laundry tub, sump, standpipe, or
other options(check your local codes). See
"Air Gap Requirements" and "Valve Drain
Requirements"sections.
The water softener uses a direct plug-in
external power supply (included). Be sure
to use the included power supply and plug
it into a nominal 120V, 60 cycle household
outlet that is in a dry location only, grounded
and properly protected by an over current
device such as a circuit breaker or fuse.
Always install the water softener between
the water inlet and water heater. Any other
installed water conditioning equipment should
be installed between the water inlet and
water softener (See Figure below).
If installing the water softener outdoors, do
not locate where it will be exposed to wet
weather, direct sunlight, extreme hot or cold
temperatures, or other forms of abuse.
PROPER ORDER TO INSTALL WATER TREATMENT EQUIPMENT
Cold Water to House
Hot Water to House
Untreated Water to
Outside Faucets
Optional
Sediment
Water
Water
Softener
Heater
DO NOT RUN HOT WATER THROUGH THE
SOFTENER. Temperature of water passing
through the softener must be less than 120° F.
Avoid installing in direct sunlight. Excessive sun
heat may cause distortion or other damage to
non-metallic parts.
When installing in an outside location you
must take steps necessary to assure the
softener, installation plumbing and wiring, are
protected from the elements, direct sunlight,
contaminantion, vandalism, insects, vermin, etc.
Do not install the softener where it would block
access to the water heater or access to the
main water shutoff.
DIMENSIONS
22-7/16"
IN
3-3/4"
OUT
TOP VIEW
IN - OUT
41-1/2"
SIDE VIEW
City Water Supply
Shut off
valve
Pressure
Tank
Filter
Well Water Supply
Well
Pump
9
14-7/16"
FRONT VIEW
OR
47-5/8"