OPERATION
IMPORTANT: When replacing the spray tips,
make sure to install the green spray tip assembly
(tip #11002) above the ReadySpace rollers and
the white spray tip assembly (tip #11005E) into the
front bumper. NOTE: The spray tip filter is not
required for ReadySpace.
ReadySpace
Spray Tip Assembly (2)
GREEN CAP
FIG. 37
Check the spray pattern direction after installing
the spray tips. The ReadySpace spray tips should
spray directly between the two rollers. The
Restorative Extraction spray pattern should
slightly overlap at a 3° angle (Figure 38).
ReadySpace Spray Pattern
Rollers
FIG. 38
4. Inspect the spray tip pattern in the two
ReadySpace flush lines (4 spray tips). If tips are
clogged, remove the flush lines and soak them in
an acetic acid solution for up to six hours
(Figure 39). Do not remove tips from flush lines.
NOTE: During ReadySpace operation the flush line
spray tips will spray every 2
ReadySpace Flush
Line Spray Tip (4)
Push retainer tab to
release spray tip.
FIG. 39
20
Restorative Extraction
Spray Tip Assembly (2)
WHITE CAP
Restorative Extraction
Spray Pattern
Front Machine Bumper
TOP VIEW
1
/
minutes for 3 seconds.
2
FLUSH LINE (2)
Home
Find... Go To..
5. Maintain the batteries (See BATTERY
MAINTENANCE).
6. Lubricate the caster grease fittings with a water
resistant grease (Figure 40).
FIG. 40
7. Lubricate all pivot points with silicone spray then
coat with a water resistant grease to maintain
smooth operation.
8. Check the machine for water leaks and loose nuts
and bolts.
9. Periodically check the belt tension on the two
brush motors. Tighten the belt if you're able to
twist it beyond 90° at midpoint (Figure 41).
FOR SAFETY: When servicing machine,
disconnect the battery connections.
FIG. 41
Nobles Strive (04- -07)