Checking the accuracy of the vertical
en
plumbing of the SK104:
GB
Place the Lock switch 3 in the "Unlocked" (
F
position.
I
Checking the upper plumbing point:
E
P
NL
DK
S
N
FIN
J
Checking the lower plumbing point:
CN
ROK
PL
HR
H
RUS
CZ
GR
Set up the laser on its tripod or wall mount bracket near point
LT
A1 at a minimum distance of 1.5 m from point B1. The hori-
LV
zontal laser is aligned in direction 1. Mark the laser dots A1
EST
and B1 with a pin.
Rotate the instrument by 180° so that it points in the opposite
SLO
direction 2 to direction 1. Adjust the instrument so that the
SK
Care and advice on operation
M
TR
B1
B2
max. 2 mm
1.5 m
1
2
A1
A1
1
2
1.5 m
B1
B2
max. 2 mm
laser beam hits point A1 exactly. If point B2 is no further than
2 mm away from point B1, then the SK104 is within toler-
ance.
)
Should your SK104 be outside of the specified toler-
ance, please contact an authorised dealership of Makita.
Display notices
Falling below or exceeding the permissible temperature
range:
The laser switches off and all symbols flash.
Outside of the self-levelling range:
The laser beam is flashing.
Pendulum locked:
The laser beam is not levelled and the Lock symbol 4 lights
up.
Care and advice on operation
Do not immerse the instrument in water. Wipe off dirt with a
damp soft cloth. Do not use aggressive cleaning agents or
solvents. Treat the instrument with the same care that you
would apply to binoculars or a camera.
Dropping or violent shaking of the instrument may damage
it. Check the instrument for any damage before using it.
Check the levelling accuracy of the instrument regularly.
Transport
To safely transport the instrument, set the Lock switch 3 to
"Locked" (
).
8