John Bean B 600 Manual Del Operador página 130

Ocultar thumbs Ver también para B 600:
Tabla de contenido
130
User Code
Code C8
Selecting the limit (threshold) value for suppression
of minor unbalance readings in grams, or ounces.
The unit of measurement depends on Code C3
setting.
Ounces:
Grams:
Range 0.12 to 0.71 oz
Range 3.50 to 20.0 g
Factory-adjusted to 0.18* oz
Factory-adjusted value is 3.5 g
Select another limit, e. g.: 0.50 oz
Threshold value display, e.g.: 3.50 g
• Select Code C8
Select another limit value, e.g.: 5.50 g
• Set the value 0.50
Press OK.
• Press ENTER
Ounces:
Grams:
Range 0.25 to 2.00 oz
Range 3.50 to 20.0 g
Factory-adjusted value is 0.25 oz
Factory-adjusted to 5.0* g
Threshold value display, e.g.: 0.25 oz
Select another limit, e. g.: 5.50 g
Select another limit value, e.g.: 0.50 oz
• Select Code C8
After the confi rmation OK, this operating mode can be
• Set the value 5.50
acquired in the permanent memory (C10).
• Press ENTER
Code C10
Storing the selected mode of operation in the
permanent memory
If a mode of operation is to be transferred into the
permanent memory, fi rst modify its status, e.g.: activate
or deactivate it and then transfer it into the permanent
memory using code C10 (it cannot be used for C4).
0* =
No storage
1 =
Data are stored in permanent memory
For storage in the permanent memory.
Press OK.
- A three-tone signal sounds to confi rm acceptance.
Code C11
Main shaft stop position
The positioning brake stops the main shaft close to the
correction position by initiating pulsing braking.
The positioning brake is activated after switch on and
after a measuring run has been carried out and found
an unbalance greater than the limit value.
• Select Code C11
• Select one of the following options:
0 = No positioning brake after measuring run.
1*= Positioning brake after measuring run for left plane.
* = Factory-adjusted mode
Tabla de contenido

Solución de problemas

loading

Tabla de contenido