2 PRODUCT DESCRIPTION

NET24N is a universal control panel for DEA System 1 or 2 24V operators automations with or without encoder.
The main feature of this control board is its ease of configuration of inputs and outputs according to any needs thus ensuring
adaptability to any type of automation. It is therefore easy to set up and exclude all unnecessary functions.

3 TECHNICAL DATA

Power supply (V)
Rated power
transformer (VA)
Fuse F2 (A)
(transformer)
Batteries
Fuse F1 (A)
(batteries input)
Outputs 24V motors (ma-
ximum output
Warning: The above values are calculated by taking the maximum power supplied by the respective processors. In absolute terms, the maximum current from
current) (A)
each output must not exceed 10A.
Auxiliaries power supply
output
"Warning" output
Electric lock output
Flashing light output
Operating temperature
range (°C)
Receiver frequency
Transmitters type of co-
ding
Max remote controllers
managed
* Values for STOP with boom ≥ 6 mt.
Livi 5/24 - Livi 8/24
Rev - Gulliver
Livi 550PL
20
TYPE 00
250 VA
120 VA
80 VA (230/22V)
(230/22V)
(230/22V)
1A
2x
2x
12V 1,3A
12V 4A
1x 5A
1x 10A
Geko
Livi 902/24
Livi 905/24
TYPE 01
230 V ~ ±10% (50/60 Hz)
150 VA
(230/22V)
2A
2x
12V 1,3A
15A
2x 5A
+24 V
max 200mA
+24 V
max 15 W
24V
max 5W or max 1 art. 110
24 V
max 15W
-20÷50 °C
433,92 MHz
HCS fix-code - HCS rolling code - Dip-switch
100
Look - Mac
Livi 500 - Livi 502
*
If you are not using DEA operators, set the pa-
rameter "Selection type of operator" to the closer
value as family type and performances.
Pass - Stop
TYPE 02
TYPE 03
4÷5 mt
≥ 6 mt
150 VA
250 VA*
(230/22V)
(230/22V)
3,15A*
2x
12V 4A
2x 5A
2x 7A*
Ghost 100 - Ghost 200