Installation:
8.
Install new greased valve cartridge into body and adjust to following torque
strengths per model type:
• 18 ft-lbs (24 N•m) for SG1PXXXX & SG2PXXXX
• 40 ft-lbs (54 N•m) for SG16XXXX & SG26XXXX
• 65 ft-lbs (88 N•m) for SG3PXXXX
• 110 ft-lbs (149 N•m) for SG36XXXX
Valve
Cartridge
9.
Install new greased diaphragm o-ring into groove on regulator body and install valve
cap.
Diaphragm
O-ring