Operation; Loopback Test (Cable With Both Ends In One Location); Remote Test (Cable With Both Ends At Different Locations); Hold - Amprobe LAN-1 Manual De Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
Testing capabilities are:
Test pin configuration for 10/100 base -T cable, 10 base-2 cable, RJ45
modular cables, AT&T 258A cable, eiA / TiA 568A/568B cables and Token
Ring Cable etc.
Verify cable continuity, open, short or incorrectly wired.
Test installed cable on wall plate or the patch panels by using the Remote
Termination module.
Buzzer sound warning for error condition.

oPERAtIoN

1.
press
� button for power oN. if no cable is attached or cable is defective,
the buzzer will sound.
2.
press BATT to verify proper operating voltage. The BATT Led will not light
and LAN-1 will not operate correctly if battery is below 7 volts.
3.
green Leds are the source indicators. Red Led's are the test indicators.
Red Led's oN indicate cable line continuity. Red Led's off indicate open
cable lines.

Loopback test (cable with both ends in one location)

1.
Connect cable with RJ-45 terminations on both ends to iN and oUT test
sockets.
2.
press
� button for power oN. press AUTo (default) or MAN button to
start scanning.
3.
AUTo scanning will step through lines 1 to 8 and ground (if connected)
and repeats until stopped.
4.
MAN scanning will go into manual mode and TeST will step through the
different lines.

Remote test (cable with both ends at different locations)

1.
Connect one cable end to oUT connector.
2.
Connect ReMoTe TeRMiNAToR to the other end of cable under test.
3.
press
� button for power oN. press AUTo (default) or MAN button to
start scanning.
4.
AUTo scanning will step through lines 1 to 8 and ground (if connected)
and repeat until stopped.
5.
MAN scanning go into manual mode and TeST will step through the
different lines.
6.
Line test results (Red Led's) are shown on the Remote Terminator.

Hold

The hoLd button saves the displayed error condition and stops testing. press
the hoLd button to return to normal operation.
6
Tabla de contenido
loading

Tabla de contenido