Fondital eBLITZ GD Serie Manual De Instalación, Uso Y Mantenimiento página 36

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Input voltage
Insulation class
Water protection class
Working temperature
Consumption in standby mode
Storage temperature
Working relative humidity
Type of setting
Temperature range
Information requirements for electric local space heaters in accordance with Annex II, point 3.a.i.2, of the
Regulation (EU) 2015/1188 of 28 April 2015 implementing Directive 2009/125/EC.
eBlitz GD5806/ eBlitz GD5810/ eBlitz GD5812/ eBlitz GD5815/ eBlitz GD5818
Item
Heat output
Nominal heat output
Minimum heat output
(indicative)
Maximum continuous
heat output
Auxiliary electricity
consumption
At nominal heat output
At minimum heat
output
In standby mode
Contact details
36
230V +/- 10% AC 50 Hz
Mod. GD5806
Mod. GD5810
Mod. GD5812
Mod. GD5815
Mod. GD5818
Class II
IP24
0 ÷ 50 °C
< 0.5 W
-20 ÷ 70 °C
0 ÷ 85 % non-condensing
Integral proportion
7°C ÷ 32°C
Model identifiers:
Symbol
Value
Pnom 0,6/1,0/1,2/
1,5/1,8
Pmin
N.A.
Pmax,c 0,6 /1,0/1,2/
1,5/1,8
elmax 0,6 /1,0/1,2/
1,5/1,8
elmin
n.d.
elSB
0,322
Fondital S.p.A.
25079 VOBARNO (Brescia) Italy - Via Cerreto, 40
Tel. +39 0365/878.31 - Fax +39 0365/878.304
e mail: [email protected] - www.fondital.com
600 W
1000 W
1200 W
1500 W
1800 W
Unit
Type of heat output/room temperature
single stage heat output and no room
kW
temperature control
Two or more manual stages, no room
kW
temperature control
with mechanic thermostat room
kW
temperature control
with electronic room temperature control
electronic room temperature control plus
kW
electronic room temperature control plus
kW
Other control options
W
room temperature control, with presence
room temperature control, with open
window detection
with distance control option
with adaptive start control
with working time limitation
with black bulb sensor
EN
Item
control
day timer
week timer
detection
Unit
no
no
no
no
no
yes
no
yes
no
yes
no
no
Tabla de contenido