When the function is activated and detected at window opening, the displayed symbol of the window
is intermittent.
When the function is deactivated the symbol of the window is not displayed.
The user can activate or deactivate this function as follows:
1.
Switch the radiator to standby state.
2.
Press "+" key for more than 3 seconds.
3.
Press "+" key to activate or deactivate the function (ON =active, OFF =not active).
4.
Press "function" key to switch to "ASC" function selection, see the next description of this function.
5.
Press "+" key to activate or deactivate "ASC" function (ON =active, OFF =not active).
6.
Press "function" key to switch to "Child protection" function selection, see the next description
of this function.
7.
Press "+" key to activate or deactivate "Child protection" function (ON =active, OFF =not active).
8.
Press "function" key: if "Child protection" function is active, the system switches to "Maximum
power in child protection" function, see the next description of this function. In case child
protection is not active, the system switches to standby mode again.
9.
Press "+" key to set the desired power percentage value among the following:
80%, 70%, 60%, 50 %, 40 %.
10.
Press "function" key to confirm the previous selections.
The system automatically quits this sequence after 30 seconds, modifications carried out are kept.
Child protection function
This function, when selected, reduces the radiator power and reduces the radiator surface
temperature accordingly, then it can be useful in the presence of children.
Moreover, this function allows to use the same radiator also in rooms smaller than those to which it
was initially intended, without too frequent ambient temperature variations (comfort improvement).
When this function is activated, the radiator power corresponds to the percentage value set by the
user (40% ÷ 80%), as indicated in the previous paragraph.
To activate/deactivate this function, see the previous paragraph "Window opening function".
Reading of consumption function
This function allows to read the radiator consumption and is expressed in kWh.
1.
Switch the radiator to standby state.
2.
Press "-" key for more than 3 seconds and until the consumption datum is displayed.
3.
Using "+" and "-" keys, it is possible to scroll through the consumption menu.
4.
Icons showing the day of the week are used to indicate the type of consumption:
1 = current day
2 = previous day
3 = current week
4 = previous week
5 = current month
6 = previous month
7 = current year
1 + 2 = previous year
1 + 3 = total
1 + 7 = indication of radiator power
5.
To quit this view, press "Function" key or wait 30 seconds.
Note: detected consumption cannot be reset.
EN
Current day
consumption
Total consumption
31