Declaration of Conformity
Model:
GENESYS™ 10 Series
Catalog Nos.:
335900, 335900A, 335900P, 335900AP, 335901, 335901A, 335901P, 335901AP
335902, 335902A, 335902P, 335902AP, 335903, 335903A, 335903P, 335903AP
335906, 335906P, 335907, 335907P
Model:
BioMate™ 3
Catalog Nos.:
335904, 335904P, 335905, 335905P
Model:
GENESYS™ 6
Catalog Nos.:
335908, 335908P
North American Plug (NEMA 5-15)
European Plug (CEE 7/7 Schuko)
United Kingdom Plug (BS 1363/A)
Thermo Electron Scientific Instrument Corporation certifies that the GENESYS 10, GENESYS 6, and BioMate 3
Spectrophotometers have been tested according to the instrumentation standards listed in this section in compliance
with IEC directives and other regulatory requirements. The equipment under test (EUT) consisted of a sample instrument
and applicable accessories, which are manufactured by Thermo Electron Scientific Instrument Corporation. The EUT
was configured to ensure that both the worst case condition, and that all of the accessories were tested. This equipment
has been tested for use in non-residential environments.
IEC Directives
89/336/EEC
Electromagnetic Compatibility Directive
73/23/EEC
Low Voltage Directive
Electromagnetic Compatibility Test Standards
IEC 61326-1
1998, Electrical Equipment for Measurement, Control, and Laboratory use - EMC Requirements. Class A Limits
IEC 61000-4-2
1999, Electrostatic Discharge Immunity Test (Test level: 4KV Air Discharge and 4 KV Contact Discharge)
IEC 61000-4-3
1998, Radiated, Radio Frequency, Electromagnetic Field Immunity Test (Test level: 3V/m)
IEC 61000-4-4
1995, Electrical Fast Transient/Burst Immunity Test (Test level: 1KV on the supply lines)
IEC 61000-4-5
1995, Surge Immunity Test (Test level: 0.5KV line to line and 1KV line to earth on the supply lines)
IEC 61000-4-6
1996, Immunity to Conducted Disturbances, Induced by Radio-Frequency Fields (Test level: 3V on the supply lines)
IEC 61000-4-11
1994, Voltage Dips, Short Interruptions, and Voltage Variations Test Level: 1 cycle/100%
CISPR 16-2
1999, Specification for Radio Disturbance and Immunity Measuring Apparatus and Methods–
Methods of Measurement of Disturbances and Immunity
Safety Test Standards
IEC 61010-1
1990 + A1 1992 +A2 1995. Safety requirements for Electrical Equipment for Measurement, Control and
Laboratory use.
CSA C22.2 No. 1010.1, plus Am 2
IEC 61010-1 1997, Safety requirements for Electrical Equipment for Measurement, Control and Laboratory use;
Part 1: General Requirements Test level: Installation Category II, Pollution Degree 2
Authorized signature:
_______________________________________ ___
Brenda Wilcox
Vice President, Molecular Spectroscopy
(For instruments manufactured after July 1, 2001)
Numbers above
Add a –02 suffix
Add a –04 suffix
Date: ____27May03____